Vocs adsorption equipment refrigeration temperature control instructions
With the continuous improvement of environmental protection requirements, each factory has also concentrated the processing of vocs gas generated in production. LNEYA vocs adsorption equipment can process various vocs gases. So how much do you know about vocs adsorption refrigeration temperature control?
The vocs adsorption water temperature control controls the flow rate of water flowing through the cooling tower by adjusting the bypass valve of the inlet and outlet water inlet pipe of the cooling side cooling tower and the regulating valve of the inlet and outlet water pipes, and ensures the constant temperature of the hot water side outlet water by controlling the frequency of the variable frequency fan.
The vocs adsorption pump frequency control controls the frequency of the hot water pump through the water supply pressure to keep the water supply pressure within the set range. The variable frequency control of the water pump maintains the unfavorable constant pressure difference of the circuit by changing the frequency of the water pump. The remote or near-end disadvantageous points can be selected according to the actual situation of the project for control. During the frequency adjustment process, the frequency of running the pump is always the same.
The functions and control strategies that can be realized by the secondary variable flow water system for vocs adsorption refrigeration are as follows:
Since the equipment room is already running, and the pipelines and sensors in the equipment room are not allowed to have any increase or decrease and changes, and no sensors are installed on the bypass pipe, the chilled water supply main pipe is not equipped with the main pipe outlet temperature sensor. In order to avoid the surge and stability of the centrifuge, it is necessary to meet the principle of the centrifuge operation after the first screw machine is operated. When the system cold load is ≤800 cold tons, the centrifuge is turned off and the two screw machines are started.
The number of vocs adsorption chilled water primary pump and cooling water pump is the same as the number of running units. It has the function of pump running time accumulation. The next pump is determined according to the running time of the pump. When the pump fails, it will give a fault in the central station. Alarm, remind you to carry out water pump maintenance operations. The secondary pump variable frequency control maintains the unfavorable constant pressure difference of the secondary circuit by changing the pump frequency. This value can be controlled according to the actual situation of the project to select the remote or near-end disadvantageous points.
The vocs adsorption equipment refrigeration temperature control as shown above, LNEYA vocs adsorption equipment, vocs gas condensation recovery unit for solvent gas recovery treatment, according to the requirements of 20g / m3 of exhaust gas environmental emission standards.
Related recommendations
-
New energy testing method and application case of temperature simulation thermostat
1952LNEYA new energy vehicle battery high and low temperature cycle test is one of the most widely used equipment in modern vehicle battery testing. Lithium battery is one of the more common batteries. What should be paid attention to when using it? ...
View details -
The Importance of Choosing a Quality Chiller Manufacturer
1668The first is professional operators.Professional refrigeration practitioners are the prerequisite for the maintenance, repair and maintenance of the chiller. If there are no professionals to work on the refrigeration equipment, it will not only c...
View details -
Effect of evaporator instrument for low temperature experiment on refrigeration system
2443According to different models, the choice of evaporators for low-temperature experiment special instruments is also different, such as box-type low temperature experiment special instruments, using water tank coil evaporator; open low temperature ...
View details -
What is VCSEL in the chip Burn-in Test? What effect does temperature have on it?
3100The full name of VCSEL is Vertical-cavity Surface-emitting Laser, the Chinese name is vertical cavity surface emitting laser. It is a kind of semiconductor laser. Semiconductor lasers are lasers manufactured using semiconductor manufacturing techn...
View details
LNEYA Thermo Refrigeration Co.,Ltd