How is the electric vehicle battery test driver grounded?
If the electric vehicle battery test is not isolated between the AC power source and the drive DC bus (such as a transformer), do not connect the non-isolated port of the DC bus or the ground of the non-isolated signal to the ground, which may result in equipment damage and personal injury. Because the common voltage of the AC is not to earth, there may be a high voltage between the DC bus ground and the earth.
In most electric vehicle battery test systems, all common ground and earth are connected together at the signal end. A variety of ground loops generated by grounding are susceptible to noise and generate flow at different reference points.
In order to keep the command reference voltage constant, Wuxi Guanya LNEYA will connect the signal ground of the driver to the signal ground of the controller, and it will also be connected to the ground of the external power supply, which will affect the operation of the controller and the driver.
It is difficult to test the grounding of the shield of an electric vehicle battery. There are several methods. The correct grounding of the shield is at the reference potential point inside the circuit. This point depends on whether the noise source and the receiving are grounded at the same time, or floating. Make sure that the shield is grounded at the same point so that ground current does not flow through the shield.
For the electric vehicle battery test to maintain a stable operating state, it is necessary to understand the operation of the above accessories.

관련 권장 사항
-
How does the cooling and heating system achieve simultaneous temperature control?
1059Temperature control system The thermostat has heating and cooling functions, and can use the same medium for continuous temperature control from -120℃~320℃. The heating and cooling system of cooling and heating system is mainly composed of four pa...
세부 정보 보기 -
냉각 순환 시스템은 증류기에서 비응축성 테일 가스를 수집하는 데 사용됩니다.
1052대부분의 정류탑은 2단계 응축 방식입니다. 첫 번째 단계는 냉각수를 사용하여 주로 상단 증기를 응축하고 두 번째 단계는 냉각수 또는 에틸렌 글리콜을 사용하여 주로 테일 가스를 처리하고 소량을 제거하는 데 사용됩니다 ...
세부 정보 보기 -
리액터용 장비는 어떻게 선택하나요?
901원자로의 장비 선택은 다음 사항에 따라 측정해야 합니다: 1. 가열 방법: 일반적으로 전기 가열은 3톤 이상이어야 하며, 외부 하프 파이프의 경우 3톤 미만에서 3톤 이상이어야 합니다.
세부 정보 보기 -
The consequences of the screw refrigerator not returning oil and the treatment method
1247In the cooling operation of the screw refrigerator, if the refrigerant is in contact with the lubricating oil, the lubricating oil in the compressor will enter the condenser with the operation of the refrigeration system and the gaseous or misty r...
세부 정보 보기