리액터용 장비는 어떻게 선택하나요?
The choice of equipment for the reactor needs to be measured by the following points:
1. Heating method: Generally, the electric heating should be greater than or equal to 3 tons, and in the case of the outer half pipe; less than or equal to 3 tons can be heated by water or steam, the temperature is less than or equal to 90 degrees; and the heat transfer oil can be 130 -280 degrees between.
2. Cooling method: generally normal temperature is 25 degrees or more; chilled water is between 5-25 degrees, equipped with a cooling machine; there is also an oil cooling, suitable for high temperature resin, but the temperature should be greater than or equal to 200 degrees.
3. Material: Generally, there are SUS304 stainless steel, Q235 carbon steel, SUS316 stainless steel, etc.;
4. Stirring method: inclined blade type with inclined angle of 45-60 degrees; anchor type with scraping edge scraping; dispersing disc type with 1000/1500/2800 rpm for shearing (for paint or powder, Hot melt adhesive (rubber); and ribbon type for high viscosity with dispersing disc (for hot melt adhesive)
5. Sealing form: generally has mechanical seal, packing seal, double sealing surface, single sealing surface;
6. Structural aspects: generally have outer half tube type (more than or equal to 2 tons); outer jacket type (more than 3 tons); inner coil; no jacket (no heating); inner coil type (suitable for small viscosity, Small fluidity)).
7. The structure of the kettle body: determined according to size, material and thickness;

Wuxi Guanya LNEYA refrigeration heating temperature control system is the first choice for the reactor equipment, ultra-high temperature cooling technology, can directly cool down from 300 degrees high temperature. No heat transfer medium evaporates at high temperature, and continuous control can be achieved with -80 to 190 degrees, -70 to 220 degrees, -88 to 170 degrees, -55 to 250 degrees, and -30 to 300 degrees without pressurization. temperature.
관련 권장 사항
-
제약 공장용 원자로 냉각 난방 시스템
10501. 프로세스 요구 사항: 2. 미디어 호환성: 3. 온도 범위: 4. 청결 요건 5. 공간 및 유지보수: 요약하면, ...
세부 정보 보기 -
Operation Instructions of Heating Cooling Circulator
1028Heating cooling circulator is a process that refrigerant transfers heat from low temperature state to high temperature state, so that its cooling can reach the state of low temperature environment, thus maintaining the low temperature state and re...
세부 정보 보기 -
Use of cold processing refrigerators for mechanical parts and comparison with liquid nitrogen
1001In the machinery manufacturing industry, the quality requirements for parts are very strict. In order to better improve the performance of machinery, improve product quality and life, a new technology-cryogenic treatment has been produced. During ...
세부 정보 보기 -
TCU 온도 제어 모델 선택 및 기술 파라미터 설명
1358TCU 온도 제어는 2사이클 단위 단일 유체 온도 제어 시스템이기도 합니다. 모델을 선택할 때 전체 온도 제어 반응에 매우 중요합니다. 적절한 반응 시스템만이 발열 및 흡수에 사용됩니다.
세부 정보 보기