How to choose a power battery test evaporator?
The corrosion of ferrous metals by salt water is very strong, and its corrosion is more severe when it comes into contact with air. Therefore, as far as the production process permits, closed loops should be used as much as possible. For volatile refrigerant circulation systems, a closed cycle must be used. In both cases, the horizontal battery tube evaporator is a suitable choice for the power battery test group. The tank immersed evaporator is used in an open circulation system with a non-volatile coolant. This type of evaporator is preferred for production processes that use iced ice cubes to make ice. Water tank immersed evaporators can also be used for power battery test refrigeration systems that cool or freeze bagged food in brine and concentrated spray air conditioning.
When the power battery test uses a tank immersed or shell-and-tube evaporator, the working temperature of the brine should be about 5 °C higher than the refrigerant evaporator temperature, and the freezing point of the brine should be 5-8 lower than the refrigerant evaporation temperature. °C (take 5 to 6 °C for the tank immersed evaporator and 6 to 8 °C for the shell and tube evaporator). For the power battery test, the cooling fan is usually used to increase the cooling temperature. For the freezing of the small cold storage, the shelf type pipe or the wall pipe and the top pipe can be used. For the low-evaporation power battery test evaporator, Note the effect of the height of the refrigerant liquid column on the evaporative temperature of the power battery test. The lower the evaporation temperature, the greater the influence of the liquid column. Therefore, certain measures should be taken to reduce the height of the liquid column in the evaporator.
The operation of the evaporator for the power battery test is relatively convenient, so it is better to choose the evaporator of the brand as much as possible.

관련 권장 사항
-
Principle Analysis of Glycol Chiller
1140Glycol chiller is an industrial chillerwith glycol as refrigerant. The structure of glycol chiller is roughly the sameas that of ordinary industrial chiller, which is composed of compressor,evaporator, condenser and electric control system. ...
세부 정보 보기 -
실험실에서 냉난방 장비 사용의 이점
1216실험실 냉난방 장비 (냉난방 통합 기계, 냉동 및 가열 사이클 장치라고도 함)는 냉난방, 난방 및 냉방을 신속하게 변환 할 수 있고 동일한 매체 (...)를 통합하는 장치입니다.
세부 정보 보기 -
불소화 액체 TCU 온도 제어 시스템의 유지보수 원리
987Fluorinated liquid TCU temperature control system should be placed in a ventilated, dry and clean place; (2) The distance between the fluorinated liquid TCU temperature control system and the partition is greater than 1m; (3) The lo...
세부 정보 보기 -
Solution to oil spill of reactor cooling and heating circulator
997When we use some reactor cooling and heating circulators, we will find that the system pressure fluctuates up and down as the temperature rises, and the oil tank is overflowing. So what are the reasons for these conditions in the cooling and heat...