What Should Be Noticed In Detail When Installing A Precision Chiller?
First, when installation, everyone needs to check whether your cold water machine works normal, whether the accessories are all right, whether there is damage, so as to avoid problems in installation.
Second, when installing, the site of the precision chiller must be a place where the balance can support the weight of the machine. Once the weight of the machine can not be borne, heap of the heap matters are behind.
Third. The environment of the precision chiller should be in the room at a temperature above 5 centigrade. There should be enough space around the precision chiller for the maintenance of the machine.
Fourth. When selecting the 정밀 냉각기, one end of the chiller should leave the tube space for the condenser, and of course, use the door or other locations.
Fifth, to determine the application of your precision chiller, the greater operation power of the chiller and the water flow rate of the evaporator and condenser should be clearly calculated.
Sixth, we must consider any special circumstances to ensure that the water flow of the precision chiller is stable.
Seventh. The pipeline design of the precision chiller should be carried out in accordance with the conventional method. In the piping, the elasticity of the pipe should be set up and the water of the evaporator should be removed.
Eighth, it is suggested that the water supply of the evaporator and condenser choose water of better quality. Once the water quality is not good, it will cause certain grime, which will affect the heat transfer and breed the microorganism bacteria, and increase the operation and maintenance cost of the machine.
Nine, the filters for water pipes should be cleaned regularly, and all interfaces should be treated with rust prevention.
관련 권장 사항
-
Advantages and disadvantages of water-cooled chillers
1133The water-cooled industrial chillers produced by LNEYA are refrigeration equipment that provides chilled water. Today we will discuss the classification, advantages and disadvantages of water-cooled chillers. Water-cooled chiller configuration: 1....
세부 정보 보기 -
초저온 냉장고의 유지 관리 및 유지 보수
1296초저온 냉장고의 유지 관리 및 유지 보수는 정상적인 사용과 수명 연장을 위해 매우 중요합니다. 부정확 한 온도 제어로 인해 보호 대상물이 손상되는 경우가 종종 발생하면 크게 ...
세부 정보 보기 -
공작 기계 스핀들에 냉각기가 필요한 이유는 무엇입니까?
924The main reasons why machine tool spindles require a chiller are as follows: Temperature Control: During the machining process, the spindle generates a large amount of heat due to high-speed rotation. If not controlled, this heat ...
세부 정보 보기 -
열유 난방 시스템 설치 및 고장 분석
1344열전달 오일 난방 시스템 장치를 설치할 때 설치 중 일부 결함을 피하기 위해 시스템에주의를 기울여야합니다. 결함이 발생하면 열전달 오일과 관련된 결함을 이해해야합니다.
세부 정보 보기