The Advantage Parameter Explanation Of The Walk-In Lab Water Chiller
In the experimental equipment, the walk-in lab water chiller is used for all kinds of electronic components in high and low temperature or hot and wet environment to test the requirements of various performance indicators. It is generally applicable to aerospace products, information electronic instruments, materials, electricians, electronic products and other industries.
The performance of the walk-in lab water chiller:
1. The machine has a wide range of temperature control, which can meet the various needs of users.
2. Using a unique balance tempering mode, it has a stable and balanced heating capacity, and can carry out temperature control of high precision and high stability. The temperature is displayed with touch screen, which is easy to read.
3. You can adjust the temperature error value to meet your more accurate test conditions.
4. With the temperature setting value automatically select the operation of the refrigeration circuit function, the operation is simple.
5. The box door is equipped with a large observation window. The test condition of the sample can be observed at any time.
6. It has the function of starting up at a high temperature and can be opened when the temperature rises to 100 centigrade in the box. It is easy to carry out the round-trip test between high temperature and low temperature.
The technical parameters of the walk-in lab water chiller:
In practical application, the temperature range of the chiller is: (-40 C, -70 C) to +100 C, the humidity range: 25%R.H to 95%R.H, the temperature fluctuation: + 0.5 C, the rise and fall temperature rate: 0.5 C /min ~ 10 C /min, the volume size is different in the selection of volume size. The selection is determined according to the actual size.
Related recommendations
-
How to replace the four-way valve of industrial refrigeration equipment?
1756The four-way valve of industrial refrigeration equipment needs to be replaced in time after a long period of use, so how to replace it? When replacing industrial refrigeration equipment, you need to first remove the connecting pipe connecting the ...
View details -
Routine maintenance of tcu multi-reactor temperature control equipment
1969TCU multi-reactor temperature control equipment is widely used in research departments such as petroleum, chemical, electronic instruments, physics, chemistry, bioengineering, physical property testing and chemical analysis, colleges and universi...
View details -
Technological Characteristics of Glycol Refrigeration System
1745At present, it is often necessary to provide process chilled water of 1-4℃ for the production line in the milk, beverage and other industries. Because the temperature of frozen water in 1-4℃ process is close to the freezing point of water at 0℃, i...
View details -
How to deal with chip failure in integrated circuit chip test?
2436The integrated circuit chip test is used in various chips, semiconductors, and component tests. Once the chip fails, the test work will stop. Therefore, the ineffective user of the integrated circuit chip test needs to know clearly. The purpose of...
View details
LNEYA Thermo Refrigeration Co.,Ltd