OBC 테스트에는 어떤 종류의 냉각기가 필요하나요?
The On Board Charger (OBC) test chiller plays an important role in the development and testing of electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEVs). OBC is a key component of the electric vehicle charging system, used to convert alternating current into direct current for charging the vehicle battery. Due to the large amount of heat generated by OBC during operation, a cooling machine is required during the testing process to simulate the thermal management of OBC under actual usage conditions.
The following are the main functions of the OBC test chiller:
Thermal performance evaluation: The OBC test cooler can help evaluate the thermal performance of the OBC under different working conditions, including heating and cooling efficiency at different charging powers.
온도 제어: By precisely controlling the temperature, it ensures that the OBC can simulate the temperature environment under real usage conditions during the testing process, which is crucial for evaluating the performance and reliability of the OBC.
Thermal management test: Test the performance of the OBC’s thermal management system under different working conditions to ensure that it can effectively control the temperature of the OBC and avoid faults caused by overheating.
Performance consistency testing: By conducting tests under different temperature conditions, evaluate the performance consistency of OBC at different environmental temperatures, ensuring that OBC can operate stably in various temperature environments.
Reliability testing: Run the OBC for a long time and conduct tests under different temperature conditions to evaluate the long-term stability and reliability of the OBC.
Fault simulation test: Simulate fault conditions such as overheating to evaluate the fault response mechanism and recovery capability of OBC.
The types of test chillers for On Board Chargers (OBCs) are divided into the following categories:
Air cooled cooling type: cooled by forced air flow such as a fan, suitable for medium-sized OBC testing, and can provide good cooling effect.
Water cooled cooling type: • Single cycle water cooling: using a single coolant circulation system, suitable for medium-sized OBC testing Dual cycle water cooling: using two independent cooling cycles, the outer cycle is used for heat exchange with the OBC, and the inner cycle is used to cool the coolant in the outer cycle. It is suitable for high-performance OBC testing and can provide more stable temperature control.
Liquid cooled chiller: • Direct liquid cooling: Directly introducing coolant into the interior of the OBC for heat exchange, suitable for high-performance OBC testing and providing efficient thermal management Indirect liquid cooling: Indirectly exchanging heat with OBC through a heat exchanger, suitable for various types of OBC testing.
Refrigerant chiller: • Compressor refrigeration: uses refrigerant to circulate through the compressor for cooling, suitable for high-performance OBC testing, and can provide precise temperature control.
Our LNEYA OBC test chiller records temperature data and other key parameters during the testing process for subsequent data analysis and performance evaluation, ensuring that the OBC can take appropriate protective measures such as automatic power-off or cooling in case of abnormal conditions such as overheating.
In summary, the OBC test chiller is one of the key equipment for evaluating the performance and reliability of OBC. By simulating the temperature environment under real usage conditions, it ensures that OBC can work stably and efficiently under various temperature conditions. This is crucial for the overall performance and user experience of electric vehicles.
Vehicle Component Test Chiller
KRY -40℃~+100℃ (1to6)
The components are cooled and heated internally through ethylene glycol aqueous solution for testing -40 ° C~100 ° C (expandable to 150 ° C) For the power battery charging management, the precision …
KRY -40℃~+100℃ (1to1)
Refrigeration, heating, temperature control, flow control Connect the tested object to a testing platform adapterThe components are cooled and heated internally through ethylene glycol aqueous solution for testing. …
KRY -40℃~+100℃ (1to2)
Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. Theequipment can control the flow and pressure independently while c…
KRY -40℃~+100℃ (1to3)
Dimension(A) cm Temperature range is -40℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. Theequipment can control the flow and…
로딩 중...
이미 마지막 에피소드에 도달했습니다!
관련 권장 사항
-
LNEYA: 모든 디테일을 디자인하는 데 집중하여 멋진 작품을 만들 수 있습니다.
1188LNEYA는 냉장 및 난방 온도 제어 분야의 뛰어난 인재를 활용하고 있으며 강력한 기술 배경을 보유하고 있습니다. 업계에서 잘 알려진 하이엔드 R&D 팀을 보유하고 있습니다. 그것은 하이 엔드 R & D 및 응용 프로그램 팀입니다 ...
세부 정보 보기 -
LNEYA 2020 배드민턴 토너먼트가 성황리에 종료되었습니다.
1289In order to enrich employees' spare time, enhance cohesion among employees, create a sunny, energetic and passionate working atmosphere, and demonstrate the company's positive, healthy and upward spirit, LNEYA held the third "Guanya Cup" badminton...
세부 정보 보기 -
코로나19에 대한 글로벌 협력, LNEYA는 능력 범위 내에서 지원 제공
1498At the current stage of virus transmission, it is imperative to study effective drugs and vaccines against coronavirus. As a manufacturer of high-precision temperature control technology, we believe that it is our responsibility to support the wo...
세부 정보 보기 -
'NCP'에 맞서 싸우며 안전하게 생산을 재개하는 LNEYA
13892020년 새해가 안개를 드리우고 있지만, 모든 것이 회복되는 순간은 결코 오지 않을 것입니다. 현재 전국의 많은 기업에서 운영 부담과 어깨에 짊어진 책임이 매우 무겁습니다. 그러나 LNEYA는 ...
세부 정보 보기