Advantages of laboratory low-temperature circulators

The laboratory low-temperature circulator can simultaneously provide constant temperature and current refrigeration, heating, and temperature control equipment. The laboratory low-temperature circulator has a reasonable structure, simple operation, and good stability.
1. The laboratory low-temperature circulator uses a compressor for refrigeration, which consumes energy and improves the exhaust temperature. The refrigerant then exchanges heat with the surrounding medium under the right conditions, transferring the heat to the surroundings. If adiabatic expansion is carried out again, the temperature will decrease.
2. The laboratory low-temperature circulator absorbs isothermal heat from high-temperature objects through an evaporator to reduce the temperature of the object to be cooled. This cycle is continuously carried out to achieve the purpose of cooling. The design of the laboratory low-temperature circulator refrigeration system uses energy regulation technology. Effective treatment methods can not only ensure the normal operation of the refrigerator, effectively control the energy consumption and cooling capacity of the refrigeration system, reduce the operating cost of the experimental box refrigeration system, and achieve a more economical state.
3. The laboratory low-temperature circulator absorbs the heat of the object to be cooled from the evaporator and evaporates it with steam. The compressor continuously extracts the steam generated by the evaporator.
4. The high-temperature and high-pressure steam compressed by the laboratory low-temperature circulator is sent to the condenser, where the cooling medium (such as water, air, etc.) releases heat and condenses into a high-pressure liquid. The pressure is reduced through a throttling mechanism to enter the evaporator. Evaporate again, absorb the heat from the cooled object, and circulate in this way.
5. After the laboratory low-temperature circulator mechanism heats up, the refrigerant changes its flow through a four-way valve. The flow direction of the refrigerant is exactly opposite to the refrigeration process. The refrigerant first passes through the evaporator, then returns to the condenser, and then returns to the compressor.
관련 권장 사항
-
유기 폐가스 정화 응축 셧다운 참고 사항
1239유기성 폐가스를 정화 및 응축하는 경우 작동 중에 고장이 발생하면 가동을 중단하고 제때 폐기해야 합니다. 그렇다면 유기성 폐가스 정화 및 응축이 종료된 후에는 어떻게 사용할 수 있을까요?
세부 정보 보기 -
2018 Automotive Testing Expo
10292018 Automotive Testing Expo (2018 Automotive Testing and Quality Control Expo) is China's relatively large vehicle and component testing and verification technology and service exhibition. Wuxi Guanya LNEYA is committed to developing battery te...
세부 정보 보기 -
테스트 벤치의 외부 순환 냉각 시스템에서 고려해야 할 측면은 무엇입니까?
1090우리 모두 알다시피, 테스트 룸에는 차량 성능과 종합적인 변속기, 도로 시뮬레이션, 전자기 호환성, 전원 배터리, 차량 환경 및 기타 테스트를 위한 냉각 시스템이 갖춰져 있어야 합니다.
세부 정보 보기 -
소형 환경 테스트 챔버 압축기는 유지 보수 후주의를 기울여야합니다.
1147원심식 소규모 환경 테스트 챔버에서 흡입 회수 장치는 일반적으로 독립 시스템이며, 필요한 경우 응축기와 증발기에 연결된 파이프 라인을 닫아 별도의 유지 보수를 할 수 있습니다. 후 ...
세부 정보 보기