What are the effects of the oil separator on the equipment analyzed by the chiller manufacturer
Oil separators use more accessories in the
chiller refrigeration system. So as users, we need to understand where the main
impact is in order to better use the equipment.
In the configuration of the chiller, the
position of the oil separator is after the compressor discharge port. After the
compressor, this arrangement is because the refrigerant is mixed with the
refrigerated lubricating oil only after compression in the compressor
compression chamber, and the oil separation operation is required after being
discharged from the compressor. Oil separation is the separation of
refrigerated lubricating oil.
Therefore, the role of the oil separator is
also quite large. Once the chiller manufacturer does not have an oil separator,
it will cause the refrigerated lubricating oil and refrigerant to enter the
condenser together, and the condenser will not work, and the condensation
effect will not be achieved.
The chiller manufacturer tells everyone
that the oil separator has a great effect on the separation of the mixture of
refrigerant and oil, which greatly affects the work of the chiller. If the
separation effect is good, the cooling effect of the entire chiller will be
very good. If the separation effect is poor, the refrigeration effect of the
entire refrigerator will also become poor. This is because once the refrigerant
and lubricating oil cannot be completely separated, a small part of the
lubricating oil will enter the condenser with the refrigerant, resulting in
defects The cooling effect.
Therefore, the existence of the oil
separator still has its effect. Once there is no oil separator, the lubricating
oil will not be recovered, precipitated, cooled and continue to be supplied to
the compressor, and the compressor will lose lubrication, thereby increasing
the gap between the components. Wear and tear improves the heat dissipation and
prevents the compressor from operating normally in a short period of time.
Of course, these chiller manufacturers have
already considered it, so all the parts that should be configured for the
chiller have already been configured.
Related recommendations
-
Chemical reaction exothermic or endothermic temperature dynamic compensation system
2178In the chemical laboratory, pilot plant and reaction process, temperature control requires the use of dynamic temperature control systems. When controlling the reactor, the exothermic and endothermic reactions must be compensated with high speed a...
View details -
Daily maintenance instructions for heating and cooling circulators
2093After the heating and cooling circulator has been running for a long time, certain maintenance work needs to be carried out, so what should be paid attention to? To ensure the normal operation of the heating and cooling circulator after it is star...
View details -
Product description for ultra-low temperature refrigeration
1940Technical parameters (low temperature cold storage project within 100 cubic meters) of Ultra-Low Temp Cold Storage 1. Medical cold storage temperature range(℃):Low-temperature storage library: -20°C to -50°C Preservation of plasma, biological ma...
View details -
The key points of using cryogenic refrigerator for cooling reaction
2231The cryogenic refrigerator is also called chiller or cryogenic refrigeration circulator. It is an experimental instrument that can achieve low temperature -110 degrees refrigeration. This kind of equipment is often used in single-fluid refrigerati...
View details
LNEYA Thermo Refrigeration Co.,Ltd