Ways to make ultra-low temperature circulating chillers more energy-efficient
In modern times, environmental protection
and energy saving is the development theme, so is the industrial chiller. Then,
how to improve your industrial chiller to be more energy conservation?
First, to prevent and reduce the pipe
scaling of ultra low temperature recirculating chillers is for enhancing the
heat transfer efficiency of condenser and evaporator.
If the make-up water is treated badly,
calcium carbonate and magnesium carbonate produced by calcium bicarbonate and
magnesium bicarbonate through heating will precipitate on the pipes, decreasing
the heat-conducting property to have an impact on the heat exchange efficiency
of condenser and evaporator and increase the electric charge by a large margin
for chiller’s operation. Apart from using water treatment technology, that you
can apply the equipment for cleaning the pipes regularly, which can save the
electric quantity and at the same time level up ultra low temperature
recirculating chiller’s effect.
Second, to adjust the operating load of ultra
low temperature recirculating chillers reasonably.
By terms of ensuring the industrial chiller
to operate safely, power dissipation of an amount of cold
energies are smaller. It should consider the operating situations of water pump
and cooling tower comprehensively while taking this method into effect.
Third, to lower condensing temperature of
ultra low temperature recirculating chillers.
On the premise of meeting the requirement
including the security of cooling-water machine and production demand, evaporating
temperature should be raised and condensing temperature should be lowered as
much as possible. Please allow me to have your attention that the cooling tower
needs to make a big change so as to keep the efficiency.
Industrial chillers divide into many
categories like screw chiller, air-cooled water chiller, water chiller and
ultra low temperature recirculating chillers. I am pleased to claim that the
energy conservation of chiller is realizable. You can contact us by
email:sales@lneya.com.
Related recommendations
-
Vocs equipment industry heat exchanger type description
2216Every accessory in the vocs device has its function, so every accessory in the vocs device can't be less. So what is the heat exchanger in the Wuxi LNEYA vocs device? What are the main types? Tank heat exchanger: Compared with the traditional heat...
View details -
Low temperature circulating chiller startup and shutdown operation
2211When the low temperature circulating chiller is turned on, it can be automatically turned on when the manual start is selected. The automatic start-up needs to open the compressor exhaust shut-off valve, start the cooling water pump and the coolan...
View details -
Thermal oil heating system installation and fault analysis
2490When the heat transfer oil heating system device is installed, it is necessary to pay attention to the system to avoid some faults during installation. If a fault occurs, it is necessary to understand the faults related to the heat transfer oil he...
View details -
The Advantage Parameter Explanation Of The Walk-In Lab Water Chiller
1905In the experimental equipment, the walk-in lab water chiller is used for all kinds of electronic components in high and low temperature or hot and wet environment to test the requirements of various performance indicators. It is generally applicab...
View details
LNEYA Thermo Refrigeration Co.,Ltd