What should I do if the fully enclosed heating and cooling thermostat alarms for lack of refrigerant? I believe that many customers will encounter this problem when they use it. In fact, this is relatively simple. As long as we know the principle of the lack of refrigerant alarm, it can be solved very well. Today I will share two points with you so that everyone will encounter this problem. It can be solved very quickly.

When we encounter a refrigerant shortage alarm in a fully enclosed heating and cooling thermostat, the first thing we have to do is to check to see if the liquid level on the expansion tank of the fully enclosed heating and cooling thermostat is at the normal level, if it expands at this time The liquid level of the fuel tank is lower than the low level, then this alarm is caused by the lack of oil in the system. What we need to do is to add new heat transfer oil in time until the system has a stable pressure and the liquid level of the expansion tank is at the normal level. It can be solved.
There is another situation that will also cause the fully enclosed heating and cooling thermostat to alarm for lack of refrigerant. That is, an alarm occurs after a period of use. At this time, we also need to check the liquid level of the expansion tank. If the heat transfer oil is lower than the low level, there must be a leak in the pipeline, which needs to be found and repaired in time. If it is not the leakage problem, then Most of it should be that the liquid level float switch of the expansion oil tank touches the wall of the expansion oil tank, causing the liquid level switch to not work normally. At this time, we need to remove the liquid level switch and re-reinforce it. The main reason for this situation may be due to The fully enclosed heating and cooling thermostat is caused by slight vibration during use.
The above are two solutions for the lack of refrigerant alarm. The alarm is a fully enclosed heating and cooling thermostat’s built-in protection, mainly to prevent the heating tube from burning dry, so when we encounter this problem, we can solve it in most cases according to the two methods shared by the editor. If it is solved No way to contact LNEYA after-sales technical support.
관련 권장 사항
-
원자로의 온도 제어를 위해 산업용 냉각기를 종료하는 팁
1093산업용 냉각기에는 다양한 액세서리와 장비가 장착되어 있습니다. 실제 사용 시 산업용 냉각기에는 정기적인 휴식 시간을 제공해야 합니다. 장기간 작동하는 동안 안정적인 성능을 유지하려면 사용자는 다음을 수행해야 합니다.
세부 정보 보기 -
다양한 고압 반응기 구성을 갖춘 고저온 제어 시스템
854고압 원자로의 다른 구성, 다른 제조업체가 가져온 제품의 품질은 동일하지 않지만주의 사항은 동일하므로주의를 기울여야합니다. 1. 지정된 위치에서 사용하려면 ...
세부 정보 보기 -
How To Vacuum The Ultra-Low Temperature Freezer Refrigeration System?
1091LNEYA ultra-low temperature freezer indoor and outdoor connection has been completed, observe the oil pump oil mark indication to see if there is enough oil, and then start the vacuum pump to see if it is normal. Then unscrew the large valve back ...
세부 정보 보기 -
플래시 고온 및 저온 테스트 냉각기의 주요 유지보수 포인트
1012플래시 고온 및 저온 테스트 냉각기 구매자가 날로 증가하고 있습니다. 많은 사람들이 구매 후 서비스 수명이 크게 줄어든다는 것을 알게됩니다. 따라서 운영 관리 및 유지 보수 담당자는 특정 전문 지식이 있어야합니다.
세부 정보 보기