High-low temperature control system with different configurations of high-pressure reactors
Different configurations of high pressure reactors, the quality of products brought by different manufacturers is not the same, but the points of attention are the same, you need to pay attention to it.
1. To be used at the designated location and follow the instructions for use. Check the test pressure, operating pressure, operating temperature and other conditions engraved on the main container, and use it within the allowable range of conditions.
2. The high-pressure reactor is a precision equipment. The sealing ring adopts the form of conical contact and sealing, and the main bolts are tightened to press them against each other to achieve the purpose of sealing. Special care must be taken for the sealing cone to avoid damage caused by various collisions.
When installing the cover, place the reactor body first, then put the cover in a fixed position and install it on the kettle body carefully. When tightening the main bolts, you must tighten them diagonally and symmetrically several times. Evenly, do not allow the kettle cover to tilt to one side to achieve a good sealing effect, and do not exceed the specified tightening torque to prevent the sealing surface from being squeezed or accelerated wear.
3. The pressure used by the pressure gauge of the autoclave should be used within 1/2 of the indicated pressure. And often compare the pressure gauge with the standard pressure gauge and make corrections. The pressure gauge for oxygen should not be mixed with pressure gauges for other gases. For safety valves and other safety devices, use equipment that has undergone regular inspections and meets the specified requirements.
When operating high-pressure reaction kettles with different high and low temperature integrated machine prices, it must be noted that the thermometer should be inserted into the reaction solution accurately. The interior of the autoclave and the gasket should be kept clean. When covering the disc flange cover, the bolts located on the diagonal line should be tightened in turn in pairs. When the measuring instrument is broken, it is mostly broken on the front and rear sides of its glass surface. Therefore, do not stand in these dangerous places during operation. When danger is expected, remove the glass and replace it with a new one.
Pay attention to the same points, but because the brands are different, the products brought are also different, and you need to buy them from regular manufacturers.
Related recommendations
-
How to choose low temperature and high temperature aging test equipment?
2254The refrigeration capacity and temperature range of materials in different industries are different. Generally speaking, the cooling capacity is divided into 80kw, 120kw, 180kw, 240kw, 360kw, and the cooling temperature ranges from -25°C to -5°C. ...
View details -
Heat transfer oil chemical temperature control system product application
1869The heat transfer oil heating and cooling temperature control system is a device with heating or lowering at the same time, that is, when the temperature of the equipped glass reactor, rotary evaporator, extraction equipment and other devices need...
View details -
How to solve the problem of insufficient cooling capacity of semiconductor cooling cycle system?
2494The semiconductor cooling cycle system is a device for cooling the semiconductor heating part. LushiA reminds that if the cooling capacity is insufficient during the operation, it is necessary to check in time to see if something has gone wrong. W...
View details -
5P hot and cold water machine installation instructions
1960The 5P hot and cold water machine is used in various industries and is used for cold treatment. So what problems do you need during installation and maintenance? If the 5P hot and cold water unit refrigeration compressor unit does not have vibrati...
View details
LNEYA Thermo Refrigeration Co.,Ltd