Influence of refrigeration factors on high temperature enclosed explosion-proof industrial chillers
Check whether the high and low temperature enclosed explosion-proof industrial chiller is the cause of its own failure. The selection must be accurate. If the model is not in place, the required refrigeration effect will also not be achieved. It is recommended that the user purchase the required refrigeration capacity Such parameters are provided to the chiller manufacturer, and the professional selection is made to achieve the required refrigeration effect.
Envirnmental factor:
The high temperature enclosed explosion-proof industrial chiller has higher requirements for the working environment, because it is cooled by hot air circulation. If the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect. There is more dust on the surface of the compressor, which leads to slow heat dissipation of the compressor, which indirectly affects the cooling effect. The refrigerant leaks or is insufficient, resulting in a decrease in the cooling effect of the chiller. The accumulation of debris or sludge in the evaporator causes the flow rate to slow down, which affects the evaporation and condensation capacity and reduces the cooling effect.
Factors affecting the cooling effect of equipment:
High-temperature enclosed explosion-proof industrial chiller condenser dust affects the heat dissipation effect. The equipped unit is operating at full load, and the ambient temperature rises, resulting in insufficient cooling power and thus affecting the cooling effect.
Insufficient refrigerant, which is what we often call Freon, will also lead to poor refrigeration performance of high-temperature enclosed explosion-proof industrial chillers. During the operation of the chiller, the liquid refrigerant in the evaporator continuously absorbs heat from the water and begins to evaporate. After the compressor is compressed and the expansion valve is throttled, it becomes a low-temperature and low-pressure refrigerant and enters the evaporator to continue. Circulation, if the use time is too long, the refrigerant will volatilize, which will affect the refrigeration effect.
Summarize
When the filter of the chiller is blocked, it will affect the heat exchange effect of the condenser, and the cooling effect of the whole machine is not good. It is necessary to check regularly and clean the filter.
Related recommendations
-
Powertrain test cooling system-chiller maintenance
2880The powertrain test cooling system-chiller is one of the cooling systems. It has the characteristics of higher application efficiency and lower total energy consumption, and has generally been favored by many companies. However, no matter what kin...
View details -
cryogenic chillers for drugs flow chemistry processes
1974Low temperature chillers used in drug flow chemistry (continuous manufacturing) processes are one of the key equipment to ensure that reactions occur under precise temperature conditions. Flow Chemistry is a continuous manufacturing technology tha...
View details -
What are the effects of power failure on liquid nitrogen cryogenic cold box?
1913Different industries have different temperature requirements for cryogenic cryostats. Of course, there are many types of cryogenic cryostats. The refrigeration methods used in different industries are different. LNEYA uses compressor refrigeration...
View details -
Different functions of reactor cooling and heating chiller on temperature
2052The cooling and heating chiller of the reactor is a kind of refrigeration machine, because its main component uses a screw compressor, which can be called the low-temperature chiller of the reactor by its name, and is widely used in industrial pro...
View details
LNEYA Thermo Refrigeration Co.,Ltd