How to judge the operating status of the chemical and pharmaceutical constant temperature control sy
Nowadays, many pharmaceutical and chemical industries use LNEYA’s constant temperature control system. How to judge its operation status during operation?
There should be no noise in the cylinder of the chemical and pharmaceutical thermostatic control system, only the normal and regular sound of the inhalation valve. The condenser cooling water should be sufficient, the water pressure should be above 0.12MPA, and the water temperature should not be too high. There should be no foot heating and frosting on the cylinder wall, and the surface temperature difference should not exceed 15-20 degrees. For refrigerated or low-temperature systems, frosting on the suction pipe can generally reach the suction port; for high-temperature conditions, the suction pipe should not be condensed Frost, condensation is normal.
Chemical and pharmaceutical constant temperature control system Crankcase oil temperature small constant temperature control system does not exceed 70 degrees and not less than 10 degrees. The lubricating oil may have foam, and the exhaust temperature should not be too high. Too high and close to the flash point of domestic refrigeration oil will be detrimental to the equipment. The condensing pressure is not easy to be too high, and the construction capacity of the condensing pressure cold storage is affected by the water source, condensing method and refrigerant. The oil level of the crankcase shall not be lower than 1/2 of the horizontal centerline of the sight glass.
Chemical and pharmaceutical thermostatic control system. The hand-touched horizontal accumulator and oil separator should be cool in the upper part and lower part, and the liquid or oil level at the junction of cold and hot. The safety valve or bypass valve should be cool at the low pressure end, otherwise the high and low pressure series gas. During operation, the evaporating pressure and the suction pressure should be similar, and the exhaust pressure and condensing pressure should be similar to the accumulator pressure.
There should be a temperature difference between the cooling water in and out of the chemical and pharmaceutical constant temperature control system. If there is no or very slight temperature difference, it means that the heat exchanger is dirty and needs to be cleaned. The system should be sealed, and no refrigerant or lubricating oil should be leaked. The shaft seal of the fluorine small constant temperature control system should not drip oil. The temperature of the shaft seal and bearing of the constant temperature control system for chemical and pharmaceutical industries does not exceed 70 degrees. The valve body of the expansion valve is evenly frosted or condensed, but there should be no thick frosting at the inlet. When the fluid passes through the expansion valve, only a dull, small sound can be heard. The pointers of the pressure gauges in the system should be relatively stable and the temperature indication should be correct.
The above conditions related to the chemical and pharmaceutical thermostatic control system can be used to judge the operation status. It is recommended that the operator observe more to determine the faulty sound in time and solve it effectively.
Related recommendations
-
5P hot and cold water machine installation instructions
1918The 5P hot and cold water machine is used in various industries and is used for cold treatment. So what problems do you need during installation and maintenance? If the 5P hot and cold water unit refrigeration compressor unit does not have vibrati...
View details -
Explosion-proof high and low temperature one machine manufacturer instructions installation point
2223After the explosion-proof high and low temperature integrated machine is delivered from the factory, it must be installed after reaching the destination. What should you pay attention to when installing? The explosion-proof high and low temperatur...
View details -
Failure Analysis of Ultra Low Temperature Chiller Supporting Distillation Equipment
2575Once the freezer used in the matching distillation equipment fails, we need to solve it in a timely and effective manner to avoid affecting the operation of the entire experiment. In the pharmaceutical, chemical and other industries, low temperatu...
View details -
Uses of Thermal Oil Heating Systems in the Pharmaceutical Industry
1935The heating temperature requirements in the pharmaceutical industry are very diverse, as different pharmaceutical processes and product preparation steps have different temperature requirements. The following are some of the heating temper...
View details
LNEYA Thermo Refrigeration Co.,Ltd













