How to deal with organic waste gas treatment refrigerant leakage?
In the process of organic waste gas treatment, if it is found that the refrigerant leaks, it is recommended to treat it in time. LNEYA organic waste gas treatment professional manufacturer then analyzes the knowledge of organic waste gas treatment refrigerant leakage.
Organic waste gas treatment VOCS gas single material or multi-material condensation recovery, the main treatment gases are: hydrocarbons such as gasoline, crude oil, fuel oil, kerosene, diesel, heavy oil, mixed hydrocarbons; aromatics: benzene, toluene, xylene, Styrene, naphtha, etc.; alcohols, ethers, ketones, esters, etc., in the event of a situation, we must now fill the leak or treatment of the refrigerant leakage, then replace the desiccant, re-vacuum treatment, Fill the appropriate refrigerant. When you find that the leaking refrigerant is partially immersed in water, stop the chiller and quickly remove the water from the tank to prevent the compressor from drawing water into the system for more serious damage.
So, what should be done if the organic waste gas treatment refrigerant is found to be insufficient? Organic waste gas treatment failure phenomenon: the whole vehicle refrigeration effect is poor, the air outlet air is only cool, and the manifold pressure gauge check finds that the high pressure is cut and the low pressure side pressure is low (when the compressor speed is 2000/mim, the ambient temperature is about 35C). The low pressure gauge index is lower than 1kg/CM square, the high pressure gauge index is lower than 10kg/CM square, and the bubble flow is visible from the sight glass.
This may be due to a refrigerant leak point in the refrigeration system, resulting in insufficient refrigerant. Treatment method Use an electronic leak detector to detect the leak point and carry out the replacement or replacement of parts. If the parts are not replaced, only the appropriate amount of refrigerant can be replenished; if the parts are replaced, the appropriate amount of refrigerating oil should be added as required, and the refrigerant should be added after the system is vacuumed.
The above is the relevant treatment of organic waste gas treatment refrigerant leakage. If the Wuxi LNEYA organic waste gas treatment equipment fails, it is recommended to solve it in time!
Related recommendations
-
Trouble shooting method for water cut off of cooling system driven by wheel motor
2103Long-term use of the wheel motor to drive the cooling system can encounter any kind of failure. For the wheel-side motor drive cooling system, if there is a water cut problem, it is very dangerous and must be dealt with in a timely and effective m...
View details -
LNEYA chip test temperature control system operation overview
2764With the development of technology, chip testing has a very high requirement for its accuracy under certain temperature requirements. So what is the understanding of the chip test system? Chip testing requires high temperature accuracy in low temp...
View details -
Low temperature circulating chiller startup and shutdown operation
2160When the low temperature circulating chiller is turned on, it can be automatically turned on when the manual start is selected. The automatic start-up needs to open the compressor exhaust shut-off valve, start the cooling water pump and the coolan...
View details -
Noise description of common faults in high and low temperature integrated equipment
2383High-low temperature integrated machine equipment may cause malfunction due to improper operation, then how to deal with noise failure of the equipment, and then analyze the noise too high. The suction of high and low temperature integrated equipm...
View details
LNEYA Thermo Refrigeration Co.,Ltd