Selection of ultra-low temperature chiller supporting the glass reactor
In order to achieve an economical ultra-low temperature environment for glass reactors, many customers will not choose multi-stage compressor refrigeration equipment with more than two stages, but use liquid nitrogen. The cost of liquid nitrogen is low, and this refrigeration method is welcomed by some users, both in experiments and in production. However, due to the low boiling point of liquid nitrogen (minus 195.8°C), the latent heat is small and it is easy to evaporate. There are also big problems with using liquid nitrogen refrigerators safely.
In the storage, transportation and application of liquid nitrogen, it is necessary to have storage and application equipment with good thermal insulation performance. Most of the liquid nitrogen related equipment and pipeline fittings on the market adopt double-walled vacuum container structure. The key factor affecting the performance of this vacuum container and accessories is the vacuum degree of the interlayer. Moreover, the use of liquid nitrogen puts forward higher requirements on the reactor temperature control method, heat preservation measures, material properties, equipment sealing and pressure control, and environmental safety measures. Glass reactors cooled with liquid nitrogen must still retain the advantage of being transparent and visible during the reaction. Moreover, liquid nitrogen is a health hazard: skin contact with liquid nitrogen can cause frostbite. If the nitrogen produced by vaporization under normal pressure is excessive, the partial pressure of oxygen in the air will drop, causing hypoxia and suffocation. Guanya Refrigeration’s ultra-low temperature freezer adopts the single-machine cascade refrigeration process, and the low temperature can reach minus 150 degrees; it adopts the secondary supercooling technology, and the refrigeration is rapid.
관련 권장 사항
-
단거리 분자 증류기의 안정적인 운영을 위한 조치
934단거리 분자 증류기가 작동 중에 비효율적이면 관련 냉동 가열 온도 제어 시스템의 사용에 영향을 미칩니다. 단거리 분자 증류기는 어떻게 안정적인 작동을 유지합니까? 증기가...
세부 정보 보기 -
특수 환경을 위한 컴포넌트 및 구성 요소 테스터
1695반도체 산업의 지속적인 발전과 함께 부품 구성 요소 테스트는 산업, 과학 연구, 제약 및 화학 산업 분야의 부품에 널리 사용되었습니다. 현재, 꽤 많은 ...
세부 정보 보기 -
Characteristic Analysis of Air Cooled Industrial Chiller
961Industrial air-cooled chillers are generally integral machines, that is, evaporator, compressor and condenser are made together. For a slightly high-power air-cooled industrial chiller, the heat dissipation of the condenser cooling fan needs to be...
세부 정보 보기 -
산업용 공냉식 냉각기 배치 시 주의사항
1510산업용 공냉식 냉각기의 품질과 사용은 매우 중요합니다. 동시에 사용자 작업은 위치 배치를 무시할 수 없습니다. 올바른 위치 배치와 고품질 장비 만이 고효율 작동을 달성 할 수 있습니다 ...
세부 정보 보기