Maintenance instructions for compressors at minus 85 degrees ultra low temperature freezer
The compressor in the ultra-low temperature freezer of minus 85 degrees is one of the main components, and its performance is very important, so maintenance is also very important.
For manufacturers of sub-85 degree ultra-low temperature freezer compressor systems, the detection and replacement cycle of compressor refrigeration oil is related to the process control of its production. If the cleanliness control of the evaporator and condenser of the system and the system piping are better, then relatively less pollutants enter the compressor, and the detection and maintenance cycle can be relatively longer.
The acidification of the sub-85 degree ultra-low temperature freezer compressor lubricating oil will directly affect the life of the compressor motor, so it should be checked regularly whether the acidity of the lubricating oil is qualified. Generally, the acidity of the lubricating oil should be replaced if it is lower than PH6. If the acidity cannot be checked, the system’s drying filter should be replaced periodically to keep the system dryness under normal conditions. If the contaminants in the refrigerating oil and the water content exceed a certain value, it is recommended to replace the refrigerating oil.
The lubricating oil in the ultra-low temperature freezer of minus 85 degrees can form a dynamic seal between the screw and the compression chamber and the male and female screws, reducing the leakage of the refrigerant from the high pressure side to the low pressure side during the compression process. The compressed refrigerant is cooled, and the oil is injected into the compressor to absorb the heat generated by the refrigerant gas during the compression process, thereby reducing the exhaust gas temperature. An oil film is formed between the bearing and the screw to support the rotor and to lubricate. The differential pressure force is transmitted, and the capacity adjustment system is driven to adjust the position of the volume adjustment slider through the action of the compressor’s loading and unloading solenoid valve, thereby realizing the compressor capacity adjustment control and reducing the running noise.
The internal lubricating oil of the sub-85 degree ultra-low temperature freezer compressor is the key to maintain the normal operation of the compressor. The general lubricating oil problems include: foreign matter mixing, causing lubricating oil pollution, blocking the oil filter; high temperature effect causing lubricating oil degradation, losing lubrication function ;-85 degrees ultra-low temperature freezer system water pollution, acidification, erosion of the motor.
Wuxi Guanya (LNEYA) sub-85 degree ultra-low temperature freezer compressors are branded manufacturers of compressors, including Emerson, Du Ling, Bitzer, Hanbell and other brands, may be less in the failure rate, but still need Regular maintenance.
Related recommendations
-
New energy vehicle quality test water cooling chiller simulation equipment
1963It is mainly used in the water cooling system stability test of new products such as electric drives, motors, reducers, and charging piles of new energy vehicles. Constant temperature, constant pressure and constant current heat test (5-85°C), h...
View details -
LED LCD display thermal test system operation process
2048The integrated semiconductor industry has developed rapidly in the past two years, which has driven other industries around it. The chip thermal test system is one of the products. In order to avoid machine failures in the LED liquid crystal displ...
View details -
Where will the reactor be used? How about the reactor temperature control system?
1808Generally, non professionals should be confused about the reactor. The reactor is composed of reactor body, reactor cover, jacket, agitator, transmission device, shaft seal device, support, etc. It is generally understood as a container with physi...
View details -
Pharmaceutical chemical industry application – Heating Reactor Temperature Control
2238The pharmaceutical chemical industry involves many chemical reactions. The traditional heating reactor temperature control work efficiency is relatively low, the production cost is relatively high, and the device is relatively cumbersome. To this ...
View details
LNEYA Thermo Refrigeration Co.,Ltd