Low temperature chilled lubricant selection considerations
When you use a cryogenic chilled, you definitely want to know about all aspects of the cryocooler. But one of the things that needs everyone’s attention is that the type of lubricant for the chilled is chosen because there are many influencing factors. When you choose, you need to choose carefully.
There are many types of compressors for cryogenic chilled. Generally, pistons, screws, and centrifugals are commonly used. Among them, the piston type and screw type compressor are in direct contact with the lubricating oil and the refrigerant, so when selecting the lubricating oil, attention should be paid to the mutual influence of the refrigerant. Secondly, the centrifugal type is only used to lubricate the rotor bearing. It is recommended to choose according to the load and the speed when selecting.
In addition to the compressor, it is also possible to select the lubricating oil according to the type of refrigerant, because the refrigerant and the lubricating oil are mutually influential, it should be noted that the selected refrigerant and lubricating oil cannot dissolve each other, and the low-temperature chilled is recommended. The viscosity of the lubricating oil should be as high as one level higher than the refrigerant. It is necessary to ensure that the lubricating oil can be lubricated after dilution, so that the operation of the low temperature freezer will not be affected.
Another option for cryogenic chilled is the evaporation temperature of the refrigerant. Generally, the corresponding freezing point lubricating oil is selected according to the evaporation high temperature and low temperature of the chilled. When freon is used as the refrigerant, the condensation point of the lubricating oil is required. Above the evaporation temperature, if it is ammonia refrigeration, the freezing point will be lower than the evaporation temperature.
Of course, if the working conditions of the cryogenic chilled are different, the lubricating oil is also a little different. If the large, medium, and heavy load is large, try to choose a lubricant with a relatively large viscosity. For a small one, you can choose a lower viscosity.
The choice of lubricating oil for cryogenic chilled is closely related to the operation of cryogenic chilled.
Related recommendations
-
Introduction of Industrial Chillers by Industry Manufacturers
2550Industrial chiller is a kind of industrial cooling equipment, which is mainly used to solve the reaction temperature control problems such as machine overheating caused by industrial production. The common reaction kettle in industrial production ...
View details -
Compressor Inspection And Routine Maintenance Of Small Water Cooled Chillers
2119When people are hungry, they have to eat, and when the machine is broken, of course, it has to be repaired. In daily use, small water cooled chiller requires regular maintenance and other operations. Today, I would like to share with you how to ju...
View details -
Selection Method of Water Cooled Chiller or Air Cooled Chiller
2157Nowadays, the application of industrial water chiller has involved various industries, including petrochemical industry, plastic industry, electronic industry, vacuum coating and so on. However, when purchasing industrial water chillers, many ente...
View details -
Instructions for using the hydrogenation reactor cooling and heating integrated system
2414There are many accessories in the hydrogenation reactor cooling and heating integrated system, from the compressor to the electrical components. LNEYA reminds you that if you find more evaporator freezing oil, it is recommended to deal with it in ...
View details
LNEYA Thermo Refrigeration Co.,Ltd












