Reactor temperature control unit TCU with PID control loop
LNEYA reaction kettle temperature control unit tcu adopts PID control loop, which has certain applications in many fields. The reaction kettle temperature control unit tcu of PID control loop adopts fully closed cycle refrigeration system, with fast cooling and heating speed and low noise.
The reaction tank temperature control unit tcu of the PID control loop can achieve a dynamic temperature control of -120 degrees to 300 degrees. The system uses existing thermal energy (such as steam, cooling water and ultra-low temperature liquids-the “primary system”) infrastructure integration To a single-fluid system or a secondary circuit that controls the temperature of the process equipment. This completes that only one heat-conducting liquid flows into the jacket of the reaction vessel (instead of direct steam, cooling water or ultra-low temperature liquid).
The reaction tank temperature control unit tcu of the high-precision PID control circuit is a high-precision constant temperature source with built-in cooling and heating. It can be used in the matching reaction kettle for constant temperature experiments, or connected to other equipment through a hose as a constant temperature source. The reaction tank temperature control unit tcu of PID control loop is widely used in petroleum, chemical industry, electronic instrumentation, physics, chemistry, biological engineering, medicine and health, life sciences, light industry food, physical property testing and chemical analysis and other research departments, colleges and universities, Enterprise quality inspection and production department.
The reaction tank temperature control unit tcu of the PID control circuit adopts high-precision PID program to control the temperature, which can directly heat and cool, and can also be used as a heat source or cold source for auxiliary heating and auxiliary cooling. It is used for chemical reaction process control in petrochemical, pharmaceutical and other For thermostats or external circulation applications of reaction kettles, automatic synthesis instruments, extraction and condensation devices, high-pressure protection and high-temperature protection of refrigeration and heating systems ensure long-term operation of the instrument.
In the practical application of the reaction tank temperature control unit tcu of the PID control circuit, in order to effectively guarantee the service life of the equipment and reduce the failure rate in use, as an operator, it is necessary to understand some necessary reaction tank temperature control units of the PID control circuit. tcu failure processing method, in order to better and more safely use the reactor temperature control unit tcu of the PID control loop.
관련 권장 사항
-
Professional introduction and application of cooling circulating water machine
1088The cooling water machine (the chiller, also known as the chiller) is an air-cooled water circulation device that does not require a cold water tower. It is a compressor-cooled design that is designed for machines, scientific instruments, or produ...
세부 정보 보기 -
Heating and cooling system for chemical reaction kettle reaction process
1225In the process of chemical chemical reaction, material temperature is an important production process parameter. For example, in salt crystallization, solution separation, organic pigment and intermediate processing, temperature control is particu...
세부 정보 보기 -
산업 등급 냉난방 시스템 배치 주의
1317산업 등급 냉난방 시스템 전원을 켜기 전에 명판에 지정된 전압이 가정용 전압과 동일한지 확인하세요. 별도의 전원 라인과 특수 소켓을 배치하는 데에도 동일하게 사용할 수 있습니다 ...
세부 정보 보기 -
LNEYA microfluidic chip test solution
1138The microfluidic chip test is a program for testing the drive control chip. The LNEYA microfluidic chip test device specializes in processing various chip tests, and has certain advantages for the development of the chip environment. In order to i...
세부 정보 보기