Structural Characteristics of Industrial Recirculating Chiller
In the chemical reaction, there are strict requirements for the reaction temperature. It is necessary to raise the temperature to an appropriate temperature to carry out the chemical reaction smoothly. After the reaction, the temperature in the reactor must be reduced to room temperature. The existing heating system of the reactor is relatively simple, so the process of reducing the temperature in the reactor to room temperature takes a long time, and the thermal energy can not be used reasonably, resulting in a waste of some resources. Therefore, a temperature control system for rapid heating or cooling is required.
The reactor cooling and heating recirculating chiller is a typical cooling recirculating chiller with heating function. It is suitable for the laboratory and can ensure the repeatability of the experimental results. The operating temperature range is – 45 ℃to 250 ℃. the reactor refrigeration and heating recirculating chiller produced by our company has compact structure, small floor area and environmental protection. It can be placed in the ventilation place of the laboratory or used inside the equipment.
Refrigeration heating recirculating chiller is a temperature controller integrating refrigeration and heating. It is composed of two systems, two computer PC boards, each controlling the corresponding system, and automatically adjusting heating or cooling through heat transfer oil circulation according to process requirements. It consists of pump, heating pipe, cooling heat exchanger, refrigeration system, temperature control system, pipeline and frame. The heat transfer oil flows between the heat medium pipe of the unit and the jacket or coil of the reactor. The circulating pump, heat transfer oil pipe, heating device and cooling device constitute the basic circuit of the heat medium.
Many chemical reactions are accompanied by a large number of endothermic or exothermic phenomena. Temperature is an important process parameter in the production process. Our recirculating chillers provide a variety of modes from small refrigeration power to large refrigeration power, from laboratory to production site, so as to provide continuous and stable process temperature control.
Related recommendations
-
Multi-stage refrigeration small temperature control compressor description
2135The function of the compressor in the multi-stage refrigeration small temperature control station system is to draw the refrigerant vapor of the evaporator and increase its temperature and pressure, which is discharged into the condenser. In the c...
View details -
Closed Refrigeration Heating Circulator Daily Maintenance Manual
2800The closed refrigeration and heating circulators of different manufacturers have a certain life span. Reasonable and correct operation and maintenance of the closed refrigeration heating circulator can effectively extend the service life. The user...
View details -
Description of working principle of high and low temperature impact test chamber
2155Spot high and low temperature impact test chamber, also known as three-box high and low temperature impact test chamber, high and low temperature impact test chamber is mainly composed of low temperature storage chamber, high temperature storage c...
View details -
High and low temperature humidity test chamber performance
23551. It has wide temperature control range, which can meet the needs of users.2. With a unique balanced temperature control method, with stable and balanced heating capacity, high precision and high stable temperature control can be carried out;The ...
View details