Summary of Maintenance Items of Glycol Chiller
During the daily operation of glycol chiller, if the maintenance is not in place, the cooling effect of glycol chiller will be reduced. Therefore, in order to improve the operation efficiency of glycol chiller, we suggest that you should carry out necessary daily maintenance.
Inspection of refrigeration system of glycol chiller: generally, various problems will inevitably occur after long-term use of glycol chiller. Once there is a fault, we should carefully check the service condition of various parts of the machine, focusing on the refrigeration system, electrical system, air system and water system, and judge whether their functions are normal. We usually check them through sound and appearance. If there are problems, we suggest to replace them in time.
Refrigerant inspection of glycol chiller: regularly check whether the refrigerant of glycol chiller leaks: it can be determined by referring to the parameters displayed on the high and low pressure meter on the front panel of the host. According to the temperature change of air temperature (winter and summer), the pressure display of glycol chiller is also different. When the low-temperature chiller works normally, the high-pressure display is 11-17kg and the low-pressure display is 3-5kg.
Inspection of cooling water system of glycol chiller: check whether the cooling water system of glycol chiller is normal, whether the fan and sprinkler shaft of cooling water tower operate well, and whether the make-up water of the built-in water tank of chiller is normal.
System cleaning of glycol chiller: the glycol chiller shall be cleaned once a year after six months of use. The main cleaning parts include cooling water tower, cooling water pipe and condenser to ensure good refrigeration effect.
Voltage and current inspection of glycol chiller: regularly check whether the voltage and electric flow of glycol chiller are stable and whether the compressor operates normally. When the glycol chiller works normally, the voltage is 380V and the current is in the range of 11a-15a.
Of course, there are many other details that need your attention.
Related recommendations
-
How to replace the four-way valve of the chilled water machine?
2531The four-way valve of the chilled water machine needs to be replaced in time after a long period of use, so how to replace it? You can look at the suggestions. When replacing the chilled water machine, you need to remove the connecting pipe conne...
View details -
How to Control Static Electricity in Ultra-Low Temperature Test Chamber?
2074When using the ultra-low temperature test chamber, in order not to affect the quality of it, we need to better control static electricity. So how to control static electricity in Wuxi crown sub-cryogenic test chamber? Static electricity in the ult...
View details -
Start-up work for new energy thermal management
2048In the pipeline selection of new energy thermal management, if the use of improper/damaged hoses and/or hose joints will result in injury, the new energy thermal management is limited by the temperature, caliber, installation method, etc. Tube, me...
View details -
Instructions for component testing of chip inspection companies
2165With the continuous development of the component testing industry, chip testing companies have sprung up, and LNEYA has also introduced component testing equipment for chip testing. The test vector of the chip inspection company is stored in the v...
View details
LNEYA Thermo Refrigeration Co.,Ltd