When to choose TCU temperature control system?
First of all, we need to know that the reaction kettle generally needs to carry out the necessary temperature control along with the chemical reaction of the material itself. Through the temperature change of the circulating medium in the jacket or coil, the temperature of the material is controlled to achieve the target temperature of the material. For the temperature control of reaction kettles in the chemical and pharmaceutical industries, the selection of temperature control equipment is relatively high. A wide working temperature range is required, and at the same time, different chemical reactions require different temperature curves. The temperature range of the TCU temperature control system developed by LNEYA is from -120°C to 250°C, and the temperature control range is wide. The PID or PLC intelligent control board can achieve percentage temperature control. One host can control multiple units of different sizes and materials. For the reaction kettle, each reaction kettle can be controlled at different temperatures, and a separate material temperature can be set to realize one heating heat exchange host and multiple refrigerant control heat exchange units to control the target temperature of different reaction kettles.
The TCU temperature control system has a unique thermodynamic temperature control system with a series of functions to meet different application requirements. Ensure accurate temperature control and good repeatability of results, short heating and cooling times, and a wide temperature range. Equipped with a new PLC controller, 7-inch color touch screen, the data parameters are clear at a glance, and the real-time temperature change is displayed in a curve. Featuring advanced pump technology to optimize heat transfer, ensure liquid circulation and high flow. Effectively prevent the glass reactor from being damaged due to soft start. Wuxi Guanya TCU temperature control system, temperature control -120~300 degrees, high precision and repeatable temperature control results, fully enclosed pipeline design, no need to replace heat transfer oil; powerful circulating pump, adjustable flow rate, convenient The operating method saves working time and use cost, and can realize continuous work in the state of unmanned monitoring. If there is a fault, it will alarm in time and shut down the system. It is widely used in process industries and production processes in fine chemical, pharmaceutical and other industries.
Related recommendations
-
You Know What Technical Problems You Need to Know before You Buy A Low Temperature Chamber
1744Question 1: Is the temperature change rate of temperature impact test the faster the better? Explanation: Is the temperature change rate faster and better in the temperature impact test? Does the temperature change rate have any effect on the tes...
View details -
Precautions for the use of explosion-proof single fluid refrigeration heating temperature control de
2047There are many types of reactors, and laboratory reactors are one of them. What is the point of attention of LNEYA reactor temperature control system-explosion-proof single-fluid refrigeration heating temperature control device? The temperature me...
View details -
Explosion-proof high and low temperature one machine evaporator use note
2142Each accessory in the explosion-proof high and low temperature integrated machine is more important. Among them, the evaporator has one of the four major accessories, and the refrigeration effect has a certain degree. What are the main choices of ...
View details -
Solution to oil spill of reactor cooling and heating circulator
1899When we use some reactor cooling and heating circulators, we will find that the system pressure fluctuates up and down as the temperature rises, and the oil tank is overflowing. So what are the reasons for these conditions in the cooling and heat...
View details