TCU 온도 제어 시스템은 언제 선택해야 하나요?
First of all, we need to know that the reaction kettle generally needs to carry out the necessary temperature control along with the chemical reaction of the material itself. Through the temperature change of the circulating medium in the jacket or coil, the temperature of the material is controlled to achieve the target temperature of the material. For the temperature control of reaction kettles in the chemical and pharmaceutical industries, the selection of temperature control equipment is relatively high. A wide working temperature range is required, and at the same time, different chemical reactions require different temperature curves. The temperature range of the TCU temperature control system developed by LNEYA is from -120°C to 250°C, and the temperature control range is wide. The PID or PLC intelligent control board can achieve percentage temperature control. One host can control multiple units of different sizes and materials. For the reaction kettle, each reaction kettle can be controlled at different temperatures, and a separate material temperature can be set to realize one heating heat exchange host and multiple refrigerant control heat exchange units to control the target temperature of different reaction kettles.
The TCU temperature control system has a unique thermodynamic temperature control system with a series of functions to meet different application requirements. Ensure accurate temperature control and good repeatability of results, short heating and cooling times, and a wide temperature range. Equipped with a new PLC controller, 7-inch color touch screen, the data parameters are clear at a glance, and the real-time temperature change is displayed in a curve. Featuring advanced pump technology to optimize heat transfer, ensure liquid circulation and high flow. Effectively prevent the glass reactor from being damaged due to soft start. Wuxi Guanya TCU temperature control system, temperature control -120~300 degrees, high precision and repeatable temperature control results, fully enclosed pipeline design, no need to replace heat transfer oil; powerful circulating pump, adjustable flow rate, convenient The operating method saves working time and use cost, and can realize continuous work in the state of unmanned monitoring. If there is a fault, it will alarm in time and shut down the system. It is widely used in process industries and production processes in fine chemical, pharmaceutical and other industries.
관련 권장 사항
-
방폭형 냉장고-기계식 생산 공장에 적합
1511LNEYA 방폭 냉장고는 주로 특수 산업 환경에서 보존하기 어렵고 휘발성 및 인화성 및 폭발성이있는 위험물을 보관하기 위해 주로 사용되는 특수 냉장고의 일종입니다. 가솔린의 개발과 함께 ...
세부 정보 보기 -
공냉식 냉각기 설치를 위한 환경 조건
1138우리 모두 알다시피, 대부분의 기계는 환경과 조건에 맞게 설치해야 합니다. 물론 산업용 공냉식 칠러도 예외는 아닙니다. 공냉식 냉각기를 처음 설치하지 않으면 많은 ...
세부 정보 보기 -
김이 나는 시스템 온도 제어 안전 요구 사항
1188김이 나는 시스템 온도 제어는 우시 구아냐 엘네야에서 설계하고 생산한 저온 냉장고 중 하나입니다. 온도 범위는 -5°C에서 -150°C입니다. 2 차 과냉각 기술이 채택되고 냉동은 ...
세부 정보 보기 -
Cooling heating temperature control system SUNDI series thermal fluid filling instructions
11681. Refrigeration heating temperature control system SUNDI series equipment before the heat conduction filling, the heat transfer liquid inlet of the heating refrigeration circulator and the heat transfer liquid outlet of the upper end of the react...
세부 정보 보기