고온 및 저온 통합 기계 장비 차단 지침
고온 및 저온 통합 기계 장비가 장시간 작동하는 경우 관리하지 않으면 고온 및 저온 통합 기계 장비가 막힐 수 있습니다. 장비 막힘을 해결하는 방법은 무엇입니까? 전나무 ...
The first thing to do is to disconnect the power supply of the equipment, open the process pipe nozzle on the compressor, disconnect the return pipe connected to the compressor of the equipment, install the repair valve, and seal it with the welding tool. A small length of copper tube tail on the low voltage side. Then disconnect the connection between the dry filter and the capillary, disconnect the compressor from the evaporator, and install a repair valve at the evaporator inlet. Charge the refrigerant from the return pipe into the evaporator and discharge it from the capillary. When the refrigerant is discharged, the charging is stopped. At this time, the dried ammonia gas is injected into the evaporator from the return pipe at a pressure of 1 MPa, so that the high-pressure brick-mixed ammonia gas is discharged from the capillary together with the refrigerant, and the charging is stopped after the cooling of the capillary port is not fogged. Ammonia. Because the dry ammonia gas has the function of absorbing moisture, it absorbs the moisture in the evaporator and the capillary, and brings the moisture out of the system with the circulation, and the refrigerant has the lipophilic property, and can be accumulated by using this characteristic. The refrigeration oil and other impurities in the pipeline are also discharged out of the system along with the cycle.
Separating the compressor of the high and low temperature integrated machine from the condenser, and installing a repair valve at the condensing inlet, charging the condenser with the refrigerant, and discharging it from the drying filter port. When the refrigerant is discharged from the filter port to be dried , stop charging. The high-pressure dry ammonia gas of 1 MPa was injected from the repair valve to the condenser, and after 2 minutes, when it was confirmed that no dirt and moisture were discharged, the dry ammonia gas was stopped and the ammonia gas cylinder valve was closed. The purpose of this is to extract moisture from the condenser and to release the oil from the system.

First connect the condenser return port of the high and low temperature integrated machine equipment to the compressor process port, and solder it with silver electrode, and then replace the dry filter. At the same time, it is injected from the compressor process port, and then soaked into the soap water. By observing whether there is a bubble, the weld of the whole system is leaked. If there is a bubble, the ammonia gas is released and re-welded with the silver electrode. Repeat the above inspection procedure for injecting gas to observe the bubbles until no bubbles emerge and there is no leakage.
Connect the pressure vacuum gauge to the compressor process nozzle of the high and low temperature integrated machine. The valve head is connected with the vacuum pump by the pressure hose. The vacuum is applied to the system for about 1 hour. The pressure in the system drops to -0.1. When the pressure is below MPa, stop vacuuming, close the pressure gauge valve, remove the vacuum pump, connect the refrigerant cylinder, and charge the system with gas in the form of gas. When the charge reaches 80% of the total amount, stop charging and connect. On the power supply, start the compression. After 10 minutes, refill the refrigerant until the required total amount is reached. Then test the machine for more than 3 hours to see if there is any blockage. Is the temperature drop inside the box normal? If it is normal, the process tube can be used. The mouth is sealed.
The blockage of the high and low temperature integrated machine equipment is solved according to these steps, and the equipment also needs regular maintenance and maintenance to make the equipment run more efficiently.
관련 권장 사항
-
열수력 원자로에 사용되는 냉동 가열 온도 제어 시스템 장비
910냉동 가열 온도 제어 시스템은 다양한 반응기, 반응기 및 증류 장비에 사용할 수 있습니다. 오늘은 열수 반응기에 적용할 때 주의해야 할 사항을 분석해 보겠습니다. 열전달 매체 ...
세부 정보 보기 -
새로운 에너지 모터 테스트 수냉 시스템의 고장률을 줄이는 방법은 무엇입니까?
1030새로운 에너지 모터 테스트 수냉 시스템은 사용 중 사용에주의를 기울여야하며, 아무리 좋은 장비를 오랫동안 사용하더라도 일부 문제가 다소 발생할 수 있습니다. 그렇다면 사용 중 장비의 고장률을 최소화하려면 어떻게해야할까요?...
세부 정보 보기 -
The Difinition and Application of Heating Cooling Circulator
1024Before discussing how to choose the right brand of heating cooling circulator, we need to know the definition and application of heating and cooling circulator. Definition: thermostatic waterbath is also called the thermostatic water tank, constan...
세부 정보 보기 -
Knowledge sharing of high-power chiller pipeline cleaning
933For many companies, due to the weak awareness of daily maintenance of high-power chillers, industrial high-power chillers have not been effectively maintained for a long time. If the industrial high-power chillers lacks the necessary maintenance, ...
세부 정보 보기