Refrigeration heating cycle device compressor precautions
The performance of the compressor in the refrigeration heating cycle device is very important. When choosing the compressor brand of LNEYA refrigeration and heating cycle device, the compressors of domestic and foreign brand manufacturers are specially selected, the performance is more reliable, but it is necessary to pay attention to the use of the compressor. There are a few things to keep in mind.
The compressor in the refrigeration heating cycle has only one correct connection, and the others are wrong. Due to miswired, the thermal protector may lose the protection function, which may cause the compressor to burn out, which generally causes the secondary coil to burn out. For the three-phase compressor, there must be a phase sequence protection device.
For a refrigeration heating system that is not fully enclosed, the refrigerant may enter the system, and the source of the system may be there. When the copper tube is cut, fine copper chips are generated, and the processing oil, impurities and other foreign materials in the system manufacturing process, and the compressor are long-term. When exposed to air, dust, water vapor enters, and welds, an oxide film is formed on the inner surface of the pipe, so it should be filled with nitrogen gas during welding.
The influence of the residue on the system in the refrigeration heating cycle system will aggravate the wear of the friction surface of the moving parts and block the oil passage of the pump. When the compressor contains tiny inclusions such as moisture, fiber, dust, etc., it may be adsorbed on the motor windings and wiring. On the column, reduce the insulation performance of the whole machine. The processing oil and the like also react with the refrigerant or the refrigerating machine oil to generate sludge and coke, and adhere to the exhaust valve piece, the suction filter, and the capillary to cause clogging.
The refrigeration heating cycle device is recommended to use a closed circulating piping system. There is no water vapor absorption at low temperature, no oil mist at high temperature, and the heat transfer oil can have a wide operating temperature. No mechanical and electronic valves are used in the entire circulation system.
Related recommendations
-
How To Choose the Ultra Low Temperature Recirculating Chiller Expansion Valve?
2016Selection and installation of the expansion valve for ultra low temperature recirculating chillers: the selection of expansion valve plays an important role in the performance of the ultra low temperature recirculating chiller refrigeration system...
View details -
What aspects need to be considered in the external circulation cooling system of the test bench?
2048As we all know, the test room needs to be equipped with a cooling system for vehicle performance and comprehensive transmission, road simulation, electromagnetic compatibility, power battery, vehicle environment and other tests. In the automobile...
View details -
Heat sink temperature application note
2048As we all know, the semiconductor industry has certain characteristics, small size, high reliability, wide working range, and has a wide range of applications in the civilian, industrial and other fields of semiconductors, but with the increasing ...
View details -
High and low temperature integrated machine equipment blockage instructions
2056If the high and low temperature integrated machine equipment is running for a long time, if it is not taken care of, it may cause the high and low temperature integrated machine equipment to be blocked. How to solve the equipment blockage? The fir...
View details
LNEYA Thermo Refrigeration Co.,Ltd