
SR & ZLF series TCU Reactor Cooling Heating Temperature Control System
애플리케이션
TCU temperature control system uses existing thermal energy (such as steam, cooling water and ultra-low temperature liquid - the "primary system") infrastructure to integrate into a single fluid system or secondary loop used to control the temperature of process equipment. It can achieve dynamic temperature control from -120℃ to 300℃.
제품 특징
제품 매개변수
모델 | ZLF-35N ZLF-35NS ZLF-35NH ZLF-35NSH |
ZLF-50N ZLF-50NS ZLF-50NH ZLF-50NSH |
ZLF-80N ZLF-80NS ZLF-80NH ZLF-80NSH |
ZLF-125N ZLF-125NS ZLF-125NH ZLF-125NSH |
ZLF-200N ZLF-200NS ZLF-200NH ZLF-200NSH |
온도 범위 | -45-250 (the max Temp is determined by the heat and cold source supplied by the user)-40-135(The maximum temperature range can be operated by using glycol water formula solution) | ||||
ZLF-N | 주 냉원 / 주 열원은 비례 조절 시스템을 통해 시스템의 흐름을 조절하고 반응 탱크의 클램핑 열을 제어하는 데 사용되며 가열 또는 냉각을위한 열교환 기 세트가 제어 또는 냉각됩니다. | ||||
ZLF-NS | Besides ZLF-N function, add one set heater used to reduce high temp | ||||
ZLF-NH | Besides ZLF-N function, add electrical heating function | ||||
ZLF-NSH | ZLF-N 기능 외에도 고온 및 전기 가열 기능을 줄이는 데 사용되는 히터 1 세트 추가 | ||||
열교환기 영역 | 3.5㎡ | 5㎡ | 8㎡ | 12.5㎡ | 20㎡ |
Electric heatingfunction H | 25kW | 35kW | 50kW | 65kW | 80kW |
With 'H' has heating function | |||||
제어 모드 | Feed forward PiD + Our special dynamic control calculation, LNEYA PLC controller | ||||
통신 프로토콜 | MODBUS RTU protocol, RS485 interface, optional Ethemet interface/R232 interface | ||||
온도 제어 선택 | 프로세스 온도 제어 | ||||
Temp feedback | The temp of three points: the inlet and outet of heat-conducing medium, material in reactor(External temp), PT100 sensor | ||||
Process temp feedback | 원자재 공정 피드백: PT100 또는 4~20mA 또는 통신 제공 | ||||
Temp accuracy | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ |
순환 펌프 | 150L/min 2.5BAR | 200L/min 2.5BAR | 400L/min 2.5BAR | 500L/min 2.5BAR | 750L/min 2.5BAR |
입력 및 표시 | 7인치 컬러 터치 스크린, 온도 그래프 디스플레이 | ||||
안전 보호 | Self-diagnosis funcion;freezer overoad protecion; high pressure switch;, overload relay; themal protection device; high temp Protection and temp faut protecion | ||||
밸브 조각 수행 | Proportional control valve control signal 4-20mA | ||||
케이스 소재 | SUS304 | ||||
연결 크기 | DN40 | DN40 | DN50 | DN65 | DN80 |
치수 cm | 150*120*185 | 180*120*210 | 180*120*210 | 225*120*240 | 225*120*240 |
Power AC380V 50HZ | 2.3kW | 3.5kW | 4.5kW | 8kW | 10.5kW |
With H power AC380V 50HZ | 27.3kW | 38.5kW | 54.5kW | 73kW | 90.5kW |
Shell materia | 냉간 압연 시트(REL7035) |
모델 | SR-35N SR-35NS SR-35NH SR-35NSH |
SR-50N SR-50NS SR-50NH SR-50NSH |
SR-80N SR-80NS SR-80NH SR-80NSH |
SR-125N SR-125NS SR-125NH SR-125NSH |
SR-200N SR-200NS SR-200NH SR-200NSH |
온도 범위 | -120~250 (the max. Temp is determined by the heat and cold source supplied by the user)-40~135(The maximum temperature range can be operated by using glycol water formula solution) | ||||
SR-N | A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansion tank |
||||
SR-NS | Besides SR- N function, add one set heater used to reduce high temp | ||||
SR-NH | Besides SR- N function, add electrical heating function | ||||
SR-NSH | Besides SR- N function, add one set heater used to reduce high temp and electrical heating function | ||||
확장 탱크 | 100L | 200L | 280L | 390L | 500L |
열교환기 영역 | 3.5㎡ | 5㎡ | 8㎡ | 12.5㎡ | 20㎡ |
Electric heatingfunction H | 25kW | 35kW | 50kW | 65kW | 80kW |
With 'H' has heating function | |||||
제어 모드 | Feed forward PiD + Our special dynamic control calculation, LNEYA PLC controller | ||||
통신 프로토콜 | MODBUS RTU protocol, RS485 interface, optional Ethemet interface/R232 interface | ||||
온도 제어 선택 | 프로세스 온도 제어 | ||||
Temp feedback | The temp of three points: the inlet and outet of heat-conducing medium, material in reactor(External temp), PT100 sensor | ||||
Process temp feedback | 원자재 공정 피드백: PT100 또는 4~20mA 또는 통신 제공 | ||||
Temp accuracy | ±1℃ | ±1℃ | ±1℃ | ±1℃ | ±1℃ |
순환 펌프 | 200L/min 2.5BAR | 250L/min 2.5BAR | 400L/min 2.5BAR | 500L/min 2.5BAR | 750L/min 2.5BAR |
입력 및 표시 | 7인치 컬러 터치 스크린, 온도 그래프 디스플레이 | ||||
안전 보호 | Self-diagnosis funcion;freezer overoad protecion; high pressure switch;, overload relay; themal protection device; high temp Protection and temp faut protecion | ||||
밸브 조각 수행 | Proportional control valve control signal 4-20mA | ||||
케이스 소재 | SUS304 | ||||
연결 크기 | DN40 | DN40 | DN50 | DN65 | DN80 |
치수 cm | 150*120*185 | 180*140*240 | 180*140*240 | 220*180*265 | 220*180*265 |
Power AC380V 50HZ | 2.3kW | 3.5kW | 4.5kW | 8kW | 10.5kW |
With H power AC380V 50HZ | 27.3kW | 38.5kW | 54.5kW | 73kW | 90.5kW |
Shell materia | 냉간 압연 시트(REL7035) |
작동 원리
(Control the temperature of the reactor material)
- The method of changing the control set value can respond to the system lag in the process as quickly as possible and obtain a smaller system overshoot. The control consists of two sets of PID control loops, which are called: main loop and slave loop. The control output of the main loop is used as the set value of the slave loop. By controlling the temperature change gradient in this way, the temperature control accuracy of the system is guaranteed.
- The specially designed hysteresis predictor generates a dynamic signal yc(t) instead of the process variable y(t) as a feedback signal. Generate an e(t) signal for the controller, so that the controller predicts that the control action has no large lag.

FOR REACTOR SYSTEMS TEMPERATURE CONTROL
One host controls 5~60 different reactors
Non-contact temperature control system in the jacket of the reaction vessel
Each reactor is independently controlled and does not affect each other





온도 제어 공급업체로 엘니야를 선택하는 이유는 무엇인가요?
18+
수년간의 경험
30000+
만족한 고객
25000
m² 생산 면적
80+
특허 기술
LNEYA 공장 방문
제품 추천