전체 방송국 검색

FLTZ Variable Frequency Series Chiller for Semiconductor Industry

반도체 산업을 위한 FLTZ 가변 주파수 시리즈 냉각기

애플리케이션

Semiconductor temperature control unit Chiller is mainly used for precise temperature control in the semiconductor production process and testing process. The company applies multiple algorithms (PID, feedforward PID, model-free self-building algorithm) in the system to achieve fast system response and high control accuracy.

제품 특징

 

 

FLTZ 5℃~90℃

 

모델 002
002W
003
003W
004
004W
006
006W
008
008W
010
010W
015
015W
온도 범위 5℃~90℃
Cooling capacity @10℃ 6kW 8kW 10kW 15kW 20kW 25kW 40kW
Internal circulating fluid volume 4L 5L 6L 8L 10L 12L 20L
확장 탱크 용량 10L 10L 15L 15L 20L 25L 35L
냉매 R410A
Refrigerating medium Silicone oil, fluorinated liquid, polyol aqueous solution, DI, etc. (DI temp needs to be controlled above 10 ℃)
연결 크기 ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1
Cooling water connection size ZG1/2 ZG1/2 ZG3/4 ZG1 ZG1 ZG1 ZG1 1/8
냉각수 흐름 @20℃ 1.5m³/h 2m³/h 2.5m³/h 4m³/h 4.5m³/h 5.6m³/h 9m³/h
치수 cm 950*380*1055 950*380*1055 950*380*1055 980*430*1400 980*430*1400 1080*600*1500 1080*600*1500

 

FLTZ  -25℃~90℃

 

모델 FLTZ-202
FLTZ-202W
FLTZ-203
FLTZ-203W
FLTZ-204
FLTZ-204W
FLTZ-206
FLTZ-206W
FLTZ-208
FLTZ-208W
FLTZ-210
FLTZ-210W
FLTZ-215
FLTZ-215W
온도 범위  -25℃~90℃
온도 제어 정확도 ±0.05℃(Steady state outlet temperature)
흐름 제어 10~25L/min 15~45L/min 25~75L/min
Cooling capacity @-15℃ 2kW 3kW 3.8kW 6kW 7.6kW 10kW 15kW
Internal circulating fluid volume 4L 5L 6L 8L 10L 12L 20L
확장 탱크 용량 10L 10L 15L 15L 20L 25L 35L
냉매 R404A
Refrigerating medium Silicone oil, fluorinated liquid, glycol solution etc
연결 크기 ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1
Cooling water connection size ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 ZG1 1/8
냉각수 흐름 @20℃ 1.2m³/H 1.6m³/H 2.6m³/H 3.6m³/H 5.5m³/H 7m³/H 10.2m³/H
치수 cm 950*380*1055 950*380*1055 950*380*1055 980*430*1400 980*430*1400 1080*600*1500 1080*600*1500
공정 온도 제어 The remote target temperature can be controlled by combining the self created model free self
built tree algorithm and cascade algorithm

 

FLTZ  -45℃~90℃

 

모델 FLTZ-402
FLTZ-402W
FLTZ-403
FLTZ-403W
FLTZ-404
FLTZ-404W
FLTZ-406
FLTZ-406W
FLTZ-408
FLTZ-408W
FLTZ-410
FLTZ-410W
FLTZ-415
FLTZ-415W
온도 범위  -45℃~90℃
온도 제어 정확도 ±0.05℃(Steady state outlet temperature)
흐름 제어 10~25L/min  5bar max 15~45L/min 5bar max 25~75L/min 5bar max
난방 Using compressor heating, prevent condenser frosting technology
Cooling capacity @-35℃ 1kW 1.4kW 1.8kW 2.5kW 3.3kW 5kW 8kW
Internal circulating fluid volume 4L 5L 6L 8L 10L 12L 20L
확장 탱크 용량 10L 10L 15L 15L 20L 25L 35L
냉매 R404A
Refrigerating medium Silicone oil, fluorinated liquid, glycol solution etc
연결 크기 ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1
Cooling water connection size ZG1/2 ZG3/4 ZG3/4 ZG1 ZG1 ZG1 ZG1 1/8
냉각수 흐름 @20℃ 1.5m³/H 2.4m³/H 3.5m³/H 5m³/H 5.5m³/H 6m³/H 8m³/H
치수 cm 950*380*1055 950*380*1055 950*380*1055 980*430*1400 980*430*1400 1080*500*1500 1080*500*1500
공정 온도 제어 The remote target temperature can be controlled by combining the self created model free self
built tree algorithm and cascade algorithm

 

FLTZ -80℃~+90℃

 

모델 FLTZ-803W FLTZ-805W FLTZ-806W FLTZ-808W FLTZ-810W
온도 범위  -80℃~+90℃
온도 제어 정확도 ±0.05℃(Steady state outlet temperature)
흐름 제어 7~25L/min  5bar max 12~45L/min 6bar max
Cooling capacityat-70℃ 0.6kW 1kW 1.5kW 2kW 3kW
난방 용량 2kW 2kW 2kW 3.5kW 3.5kW
Internal circulating fluid volume 4L 5L 6L 8L 10L
확장 탱크 용량 10L 10L 15L 15L 20L
Heat-conduction medium 불소화 액체
연결 크기 ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG3/4
Cooling water connection size ZG3/4 ZG3/4 ZG3/4 ZG1 ZG1
Cooling water@20℃ 1.8m3/h 2.5m3/h 3m3/h 5m3/h 6m3/h
회로 차단기 25A 25A 32A 40A 50A
치수 cm 550*700*1750 650*850*1850 700*850*1850 700*850*1850 800*1200*1850
공정 온도 제어 The remote target temperature can be controlled by combining the self created model free self
built tree algorithm and cascade algorithm

 

FLTZ -100℃~+90℃

 

모델 FLTZ-1002W FLTZ-1004W
온도 범위  -100℃~+90℃
온도 제어 정확도 ±0.05℃(Steady state outlet temperature)
흐름 제어 7~25L/min 12~45L/min
Cooling capacityat-90℃ 1.5kW 3kW
난방 용량 3.5kW 5.5kW
Internal circulating fluid volume 5L 8L
확장 탱크 용량 10L 15L
Heat-conduction medium 불소화 액체
연결 크기 ZG3/4 ZG3/4
Cooling water connection size ZG3/4 ZG1
Cooling water@20℃ 50L/min 2bar~7bar 100L/min 2bar~7bar
회로 차단기 32A 63A
공정 온도 제어 The remote target temperature can be controlled by combining the self created model free self
built tree algorithm and cascade algorithm

가변 주파수 펌프는 순환 유압 및 유량을 조절할 수 있습니다.

Communication function

애플리케이션

반도체 FAB 공정의 온도 제어 장치

반도체 제조는 환경 요건이 매우 까다로운 공정으로, 많은 공정 단계가 온도에 매우 민감합니다.
정밀한 온도 제어를 통해 증착된 필름의 균일한 두께와 정확한 구성을 보장하여 칩 성능과 수율을 향상시킬 수 있습니다.

반도체 패키징 및 테스트 공정용

반도체 패키징 및 테스트 공정은 웨이퍼 테스트, 칩 패키징, 패키징 후 테스트 등 반도체 생산 공정의 핵심 연결고리입니다. 이 공정은 높은 수준의 정확성과 신뢰성뿐만 아니라 제품 품질과 성능을 보장하기 위해 엄격한 온도 관리가 필요합니다.

Such as chillers that control the processing temperature on the Fab equipments.

Cooling of CMOS/CCD sensors in semiconductor metrology systems.

Recirculating Chiller for semiconductor metering AOI system.

주로 에칭 장비용으로 설계된 단일 채널 공랭식 쿨러입니다. 챔버 측벽에 독립적인 온도 제어를 제공하는 데 사용됩니다.

Used for plasma bevel etch and deposition; Thermal Atomic Layer Etching of Metal Tungsten.


창립 이래 2006를 통해 30,000명의 고객 혁신과 신뢰성을 입증하는 여러 특허를 보유하고 있습니다. 당사의 냉각기는 100 대학 전 세계 실험실 프로젝트와 20개국. 엄격한 품질 관리를 통해 최고의 품질을 보장합니다. 3단계 품질 관리 프로세스: 육안 검사, 성능 테스트, 전기 안전 테스트. 우수성을 향한 당사의 노력은 다음과 같이 더욱 뒷받침됩니다. 연중무휴 고객 지원 약속. 또한 미국, 캐나다, 호주, 러시아, 한국에 대리점을 두고 있어 냉각기 요구 사항을 충족하는 신뢰할 수 있는 글로벌 파트너입니다. 프로젝트의 품질과 지원을 위해 lneya를 선택하세요.
18+

수년간의 경험

30000+

만족한 고객

25000

m² 생산 면적

80+

특허 기술

*
*
제출하기....
성공적으로 제출되었습니다!
제출에 실패했습니다! 나중에 다시 시도하십시오.
이메일 오류!
전화 오류!