증류로 용매 회수 온도를 제어하는 방법은 무엇입니까?
1. If the product quality is not affected by the presence of air at a higher temperature, it can be recovered at normal pressure first, and when the temperature exceeds the normal pressure boiling point of the desolvent by 10 degrees, when the solvent cannot be evaporated, change the receiving bottle, and then reduce Pressure, the degree of vacuum rises slowly from -0.01mpa to the maximum according to the flow rate. Continue to keep for 0.5 hours until no liquid flows out.
2. If the product quality is affected by the presence of air at a higher temperature, you can first evacuate to the maximum, and then slowly heat up to a temperature 10 degrees higher than the normal pressure boiling point of the desolvated according to the liquid outflow speed. Continue to keep for 0.5 hours until no liquid flows out. However, if you want to recover the solvent in this way, it is best to cool the receiving bottle and condenser with ice water.
From the perspective of process design, it is necessary to fully understand the physical parameters of the materials involved in the process, and adopt a reasonable distillation method and heating medium. The selection of the distillation method is considered from the boiling point and range of the solvent. High boiling point materials When dealing with materials that are difficult to volatilize (boiling point above 150°C under normal pressure), vacuum distillation should be used; for medium volatile materials (boiling point under normal pressure is about 100°C), atmospheric distillation or reduced pressure should be used. suitable. In order to consider reducing the risk in extreme cases, that is, the continuous heating condensation fails and the system is closed, it is best to use hot water as all heating media if conditions are met. (for batch distillation)
In pharmaceutical and chemical industry, we may have heard such a process description, that is, “concentrate to dryness” and concentrate to “paste”; There is a “dry pot” situation.
For batch distillation and concentration, the following methods are usually adopted to reduce the risk of the process:
Control temperature: choose the heating medium with the highest temperature lower than the decomposition temperature (it is recommended to obtain the decomposition temperature through DSC test or ARC test, and the test sample should be representative, which is also the most effective source of safe operating temperature); vacuum distillation instead of normal pressure Distillation (lower distillation temperature);
When recovering waste liquid or solvent, choose continuous distillation instead of batch distillation.
Select the appropriate distillation equipment, some impurities or metal ions can catalyze the decomposition of the material (equipment selection, material should meet the process requirements).
Interlock: prevents ultra-gentle “steam dry”. The high temperature interlock closes the heating medium, and the low liquid level interlock closes the heating medium.
Some of the above content comes from the Internet, if you have any questions, please contact us: sales@lneya.com
관련 권장 사항
-
LNEYA 스크류 냉각기의 증발기 특성
1673스크류 칠러의 냉각 용량은 전체 장치의 에너지 소비 및 운영 경제성과 직접적인 관련이 있으므로 주목할 가치가 있습니다. 특히 콜드 스테이션을 설계 할 때 단일 냉각기가 없습니다.
세부 정보 보기 -
Failures of Heating Cooling Circulators
1015The heating cooling circulator can be used in many chemical pharmaceuticals and laboratories. Then, how to solve the failures of the heating cooling circulator?Failure of circulating pumpThe failure of the circulating pump is generally the heat ov...
세부 정보 보기 -
What should I pay attention to when replacing a water-cooled chiller compressor
1054Once the compressor of the water-cooledchiller fails, the compressor needs to be replaced in time, but the replacementof the compressor is not as simple as imagined.Before the water-cooled chiller compressoris replaced, the reasons for the dama...
세부 정보 보기 -
How to solve the shortage of cooling in the semiconductor cooling cycle system
1163The semiconductor cooling cycle system is a device for cooling the semiconductor heat-generating part in the refrigeration equipment. If the cooling capacity of the LNEYA semiconductor cooling circulation system is insufficient during operation, i...
세부 정보 보기