The amount of cooling capacity of the screw chiller is directly related to the energy consumption and operational economics of the entire unit, which is worthy of attention. Especially when designing a cold station, there is no single chiller in the general situation. This is mainly because when the screw chiller fails or is shut down for maintenance, it will not stop production. Instead, the reasonable unit should be selected according to the production situation. The number of units. When the water is filled, install the high-level automatic deflation valve, and only the vent valve of the vent valve of the pump outlet pipe (hereinafter referred to as the spout) is not installed.
When the water pump is turned on, the water flow at the spout is in the state of a musical fountain. The high and low jets slowly bring out the air in the system. As the jet flow becomes higher and more stable, the air in the system is cleaned. When the screw chiller has a flow of up to 6 meters, it will end when the nozzle is no longer dropped. Close the valve at the spout, the pressure at the outlet of the pump is 0.25 MPa, and the chiller is turned on smoothly.

LNEYA screw chiller observes Y-Δ time delay relay, the correct value is 3.5 seconds, the simulation runs, the starting load sequence is: 25% solenoid valve – liquid supply valve, compressor (simultaneous) –50% solenoid valve – 75% electromagnetic Valve – 100% solenoid valve. Observe the Y-Δ start delay time, such as too long or too short, to adjust. Stop process: 100% solenoid valve – 25% solenoid valve – liquid supply valve, compressor (simultaneous) stop. The high and low jets slowly bring out the air inside the system as the jet is getting higher and higher and more stable.
It shows that the air in the system is more clean. When the water flow in the nozzle is as high as 6 meters and no longer falls, the jet will end. Close the valve at the spout, the pressure at the outlet of the pump is 0.25 MPa, and the chiller is turned on smoothly. Thorough inspection of the closed pressure test object: whether the support hanger is stable and firm; whether the connection work of the pipeline has been completed and passed the inspection; the joint of the screw chiller and other parts to be inspected are not painted and insulated; the elevation of the pipeline The slope should be checked and passed. The pressure test table must be inspected.
관련 권장 사항
-
Vocs 흡착 장비 냉장 온도 제어 지침
1134환경 보호 요구 사항이 지속적으로 개선됨에 따라 각 공장은 생산 과정에서 발생하는 vocs 가스 처리에도 집중하고 있습니다. LNEYA 보컬 흡착 장비는 다양한 보컬 가스를 처리 할 수 있습니다. 그래서 당신은 얼마나 알고 있습니까?
세부 정보 보기 -
실험실 냉난방 서큘레이터 선택 가이드
1096실험실 냉각 및 가열 순환기 장비를 구매할 때 핵심은 생산 요구 사항을 충족하고 생산량을 가속화하는 것입니다. 따라서 장비 및 기술 솔루션의 특성을 이해해야합니다 ...
세부 정보 보기 -
LNEYA 2020 배드민턴 토너먼트가 성황리에 종료되었습니다.
1292In order to enrich employees' spare time, enhance cohesion among employees, create a sunny, energetic and passionate working atmosphere, and demonstrate the company's positive, healthy and upward spirit, LNEYA held the third "Guanya Cup" badminton...
세부 정보 보기 -
열수력 원자로에 사용되는 냉동 가열 온도 제어 시스템 장비
915냉동 가열 온도 제어 시스템은 다양한 반응기, 반응기 및 증류 장비에 사용할 수 있습니다. 오늘은 열수 반응기에 적용할 때 주의해야 할 사항을 분석해 보겠습니다. 열전달 매체 ...
세부 정보 보기