TCU 온도 제어 시스템은 언제 선택해야 하나요?
First of all, we need to know that the reaction kettle generally needs to carry out the necessary temperature control along with the chemical reaction of the material itself. Through the temperature change of the circulating medium in the jacket or coil, the temperature of the material is controlled to achieve the target temperature of the material. For the temperature control of reaction kettles in the chemical and pharmaceutical industries, the selection of temperature control equipment is relatively high. A wide working temperature range is required, and at the same time, different chemical reactions require different temperature curves. The temperature range of the TCU temperature control system developed by LNEYA is from -120°C to 250°C, and the temperature control range is wide. The PID or PLC intelligent control board can achieve percentage temperature control. One host can control multiple units of different sizes and materials. For the reaction kettle, each reaction kettle can be controlled at different temperatures, and a separate material temperature can be set to realize one heating heat exchange host and multiple refrigerant control heat exchange units to control the target temperature of different reaction kettles.
The TCU temperature control system has a unique thermodynamic temperature control system with a series of functions to meet different application requirements. Ensure accurate temperature control and good repeatability of results, short heating and cooling times, and a wide temperature range. Equipped with a new PLC controller, 7-inch color touch screen, the data parameters are clear at a glance, and the real-time temperature change is displayed in a curve. Featuring advanced pump technology to optimize heat transfer, ensure liquid circulation and high flow. Effectively prevent the glass reactor from being damaged due to soft start. Wuxi Guanya TCU temperature control system, temperature control -120~300 degrees, high precision and repeatable temperature control results, fully enclosed pipeline design, no need to replace heat transfer oil; powerful circulating pump, adjustable flow rate, convenient The operating method saves working time and use cost, and can realize continuous work in the state of unmanned monitoring. If there is a fault, it will alarm in time and shut down the system. It is widely used in process industries and production processes in fine chemical, pharmaceutical and other industries.
관련 권장 사항
-
The consequences of the screw refrigerator not returning oil and the treatment method
1251In the cooling operation of the screw refrigerator, if the refrigerant is in contact with the lubricating oil, the lubricating oil in the compressor will enter the condenser with the operation of the refrigeration system and the gaseous or misty r...
세부 정보 보기 -
집적 회로 온도 제어 장치 연구 설명
1026현재 집적 회로 온도 제어는 집적 회로, 반도체 및 칩 산업에서 사용됩니다. 따라서 이러한 산업의 테스트 요구 사항을 충족하려면 집적 회로 온도 제어가 필요합니다. 현재 ...
세부 정보 보기 -
The Importance of Choosing a Quality Chiller Manufacturer
801The first is professional operators.Professional refrigeration practitioners are the prerequisite for the maintenance, repair and maintenance of the chiller. If there are no professionals to work on the refrigeration equipment, it will not only c...
세부 정보 보기 -
The use and characteristics of the SUNDI series of high and low temperature cooling circulators
1299The SUNDI series of high and low temperature cooling circulators are equipment for direct or auxiliary heating in the fields of biology, physics, chemical engineering, medical treatment, environmental protection, etc. Moreover, the temperature con...
세부 정보 보기