Troubleshooting of Common Faults of Industrial Water Chiller
As we all know, with the rapid development of modern industrial technology, in order to improve production efficiency, improve product quality and reduce consumption costs, the demand for temperature control equipment in the process is higher and higher, but there are more and more product quality problems about some industrial water chillers, So we simply analyze some common problems about industrial water chillers.

Abnormal temperature at the inlet and outlet of cooling water: the water temperature at the inlet of condenser is too high (higher than 32 ℃), first check whether the fan of cooling tower can be reversed (there are such examples in practical engineering). Then, after technical demonstration and on the premise of feasibility, adjust the blade angle of the fan to improve the air volume of the fan.
Another phenomenon often occurs in the system with multiple cooling towers in parallel. When the local load is running, the temperature difference between the inlet and outlet of the condenser is too small. It is necessary to check whether each cooling tower has been equipped with an electric valve, or whether the set electric valve fails to form a cooling water bypass, which can not be cooled completely.
The differential pressure at the inlet and outlet of cooling water is abnormal. According to the relevant refrigeration theory, the heat release of the condenser will directly affect the refrigeration capacity. Therefore, the user should first check the cooling water system based on the pressure loss value on the main engine. If the pressure difference obtained from the value of the pressure gauge at the inlet and outlet greatly exceeds the normal value, it indicates that there are sundries at the inlet of the condenser.
관련 권장 사항
-
Instructions for cold assembly of bearings in ultra-low temperature industrial refrigerators
1019The refrigeration system of ultra-low temperature industrial refrigerators generally adopts the working principle of cascade refrigeration, and two fully enclosed compressors are used as high and low temperature compressors. The copper tube of the...
세부 정보 보기 -
Analysis of the reasons for non-refrigeration of cryogenic refrigeration equipment
1116Ultra-low temperature refrigeration equipment is mainly used in industrial cold processing. Unlike some manufacturers of ultra-low temperature refrigeration equipment, LNEYA ultra-low temperature refrigeration equipment uses environmentally friend...
세부 정보 보기 -
온도 조절기 시스템을 배치할 때 주의해야 할 사항은 무엇인가요?
971다른 제조업체에서 생산하는 고온 및 저온 서모 스탯 시스템의 크기와 성능에는 특정 차이가 있습니다. 사용자는 구매 후 배치 할 때 배치 방법에주의를 기울여야합니다.
세부 정보 보기 -
How is the refrigerant installed in the vocs condensing unit?
1304The vocs condensing equipment is LNEYA's equipment for condensing adsorption of various vocs gases. Among them, the refrigerant of vocs condensing equipment is also indispensable. So, how should the refrigerant be treated? For various refrigeratio...
세부 정보 보기