공냉식 냉각기 화학 반응 주전자의 냉동 장치에 대한 문제 해결 방법
If air enters into the air-cooled chiller refrigeration unit system of the chemical reaction kettle, the impact will be many. Enter the air circulation system first, the pressure will rise, the heat dissipation effect of the condenser will also be affected, and even the air-cooled cold water mechanism refrigeration unit of the chemical reactor will not operate as a result.

Therefore, we must usually develop the habit of inspections, and we should not close one eye when we find abnormalities. If we ignore small problems, they may develop into major problems.
In some cases, equipment problems are caused by long-term use. Machines, like people, always operate, and problems are inevitable. There are two types of air-cooled chiller chemical reaction kettle refrigeration unit, air-cooled and water-cooled, no matter which type, in the case of long-term use, the refrigeration system may leak. But as long as we seize the right time to deal with it, it will not cause any serious impact.
The air-cooled chiller chemical reactor refrigeration unit has entered the air. What we have to think about is how to vent it?
At this time, it depends on what kind of refrigeration system it uses. The ammonia refrigeration system is different from the Freon system.
If it is a Freon system, its bleed operation steps are as follows: close the condenser or liquid reservoir outlet valve; start the compressor; stop; let the high-pressure gas escape from the bypass hole. When the air is exhausted, the screw plug should be tightened, the exhaust valve stem should be reversely rotated, and the bypass hole should be closed.
If it is the pharmaceutical reactor refrigeration unit group of the ammonia refrigeration system, its venting step is as follows:
When using an air separator to discharge air, keep the air separator normally open and all other valves should be closed; the intake valve should be properly opened; the liquid supply valve should be opened slightly; the air discharge valve interface should be opened to the water to see the change of rising bubbles in the water. When stopping the air release, the air release valve should be closed first, in order to prevent ammonia gas from leaking out, and then close the liquid supply throttle valve and the mixed gas inlet valve. The purpose of this is to prevent the pressure in the air vent from rising, and the return valve should not be closed.
Wuxi Guanya (LNEYA) reminds: In order to avoid wasting refrigerant, the time of each deflation should not be too long, and it can be performed multiple times in a row.
관련 권장 사항
-
Maintenance instructions for compressors at minus 85 degrees ultra low temperature freezer
1098The compressor in the ultra-low temperature freezer of minus 85 degrees is one of the main components, and its performance is very important, so maintenance is also very important. For manufacturers of sub-85 degree ultra-low temperature freezer c...
세부 정보 보기 -
반도체 웨이퍼 온도 제어의 냉동 원리 설명
1318반도체 웨이퍼 온도 제어 냉동 시스템의 작동에서 특정 작동 유체의 상태 전환이 사용되며 필요한 열 Q0은 저온의 열원에서 추출되고 열 Qk는 센 ...
세부 정보 보기 -
-
Trouble shooting method for refrigeration device of air-cooled cold water mechanism chemical reactio
1175If air enters into the air-cooled coldwater mechanism refrigeration unit system of the chemical reaction kettle, theimpact will be many. Enter the air circulation system first, the pressure willrise, the heat dissipation effect of the condenser...
세부 정보 보기