고온 및 저온 액체 순환 냉각기의 얼음 막힘을 해결하기 위한 작은 쿠데타
In the operation of high and low temperature liquid circulating chillers, ice blockage is a relatively common fault. Based on the experience of relevant manufacturers, we have specially compiled relevant tips for dealing with ice jams.
In the pipeline of the high and low temperature liquid circulating chiller, if ice blockage occurs, it is recommended to replace the damaged pipe section and repair the missing spot welding first, and redo and tighten the loose threaded joint. In order to ensure that there is no leakage in the high-pressure test of the high and low temperature liquid circulating water chiller pipeline. The high and low temperature liquid cycle chiller refrigeration cycle system pipeline is divided into high pressure section and low pressure section, flushed with four-recording carbon, and purged with nitrogen to seal for later use.
At the same time, the high and low temperature liquid circulating chiller compressor unit must be strictly processed in accordance with the steps, replacing the new filter of the high and low temperature liquid circulating water chiller, and then blown and sealed for use. The high and low temperature liquid circulating chiller refrigeration cycle system pipeline is unsealed and the compressor unit is quickly assembled After that, perform quantitative charging of the refrigerant, and wait for five minutes (waiting for the static equilibrium of the pressure in the high-pressure zone and low-pressure zone in the refrigeration cycle system pipeline) to power on and test the machine.
When the user usually faces the operation of high and low temperature liquid circulating chillers, they need to pay attention to moisture prevention and seal or seal the parts of the high and low temperature liquid circulating water coolers that are not being repaired. Maintenance is carried out in rainy weather.
However, there is always a case in case. For high and low temperature liquid circulating chillers with slight ice blockage after maintenance, the refrigerant can be recovered, replaced with new filters, or connected in series with a large cubic freezer filter at the high-pressure exhaust end, or even Refill the refrigerant quantitatively.
There are one or two ways to face the phenomenon of ice blockage in high and low temperature liquid circulating chillers. If the user does not know how to solve it, do not solve it blindly by himself. It is recommended to find a professional maintenance person to solve it.
관련 권장 사항
-
대형 열충격 테스트 챔버의 고장을 제거하는 방법은 무엇입니까?
1042기술이 계속 발전하고 개선됨에 따라 LNEYA는 대형 열충격 시험 챔버 운영자에게 엄격한 요구 사항을 권장합니다. 부적절하게 사용할 경우 운영자는 이러한 문제를 적시에 직면하고 해결할 수 있어야 합니다. 큰 T ...
세부 정보 보기 -
What Are the Differences Between Low Temperature Test Chamber and Refrigeration?
1303The low temperature test chamber, you can see by its name, probably means to do cryogenic test. It is more important in our refrigeration equipment. The small series of low temperature test chamber tells you that the refrigeration of low temperatu...
세부 정보 보기 -
화학 원료에 저온 냉각기가 필요한 이유는 무엇일까요?
930화학 원료 생산 공정에서 저온 냉각기를 사용하는 주된 이유는 다음과 같습니다: 온도 제어: 많은 화학 반응은 온도에 민감하며 정밀한 온도 제어가 필요합니다 ...
세부 정보 보기 -
급격한 온도 변화 테스트 챔버 온도 제어 지침
1145급격한 온도 변화 테스트 챔버의 습도 범위 선택은 습도 지수 또는 이슬점 온도 다음에 해당 온도 범위를 표시해야한다는 점에 유의해야합니다. 상대 습도 때문에 ...
세부 정보 보기