What is the reason why the industrial chiller system cannot be cooled
Let the LNEYA technical engineer explain
the reason for everyone:
The first one: The chiller system fails to
lower the temperature during the first use, or there is a problem with the
installation of the industrial water chiller, cooling tower, circulating water
pump and piping. Need to check carefully according to the installation drawing.
The second one: It may be because the
pipeline is connected to various equipment for a long time, and impurities
accumulate in the water source, which causes the water flow to become smaller.
Therefore, we must clean the pipes between the equipment.
Third: If this problem occurs during the
first use, it may be caused by a mismatch of the chiller and a shipping
problem. Because the industrial water chiller has undergone 100% performance
testing before leaving the factory to ensure the normal operation of the unit.
Finally, if it is a chiller that has been
used for half a year or 1-2 years, it may be caused by a leak of Freon in the
cooling system of the chiller. It is recommended to find out the leaks,
re-soldering, and re-soldering the refrigerant. The heat exchanger of the
industrial water chiller is dirty and needs to be cleaned. Remember to clean it
regularly in the future.
The operation of any industrial water chiller
system is inseparable from the participation of refrigerants. Therefore, the
shortage of refrigerant will also affect the normal operation of industrial
chillers, leading to reduced cooling capacity or even shutdown
of industrial water chillers. This is also the main reason for the shrinking
capacity of industrial chillers.
관련 권장 사항
-
분자 증류 냉각 및 가열 온도 제어 사용 시 주의사항
1060The SUNDI series of LNEYA refrigeration and heating temperature control system are used together to control the temperature in the process of molecular distillation. What should be paid attention to in use? If the molecular distillation method ca...
세부 정보 보기 -
Vocs condensation adsorption technology energy control instructions
1322The vocs condensation adsorption technology has been developed under the current trend of environmental protection. The LNEYA vocs condensation adsorption technology uses condensation adsorption technology. In order to save operating costs, it is ...
세부 정보 보기 -
How to Solve the Problem that Water 10hp Refrigerator Can’t Produce Water
1124Wuxi guanya has cold plate freezer for sale for the industrial cold treatment.Well,how to solve the problem of water outlet fault of 10hp cold plate freezer?Therefore,I have sorted out the relevant solutions for the water outlet fault of 10hp cold...
세부 정보 보기 -
Explanation of Abnormal Condenser Temperature of Glycol Chiller
1216In the glycol chiller, the condenser temperature is the saturation temperature when the refrigerant in the condenser condenses under the steam pressure. Once the condenser temperature in the glycol chiller is abnormal, we should analyze the specif...
세부 정보 보기