What are the influences on the refrigeration factors of the enclosed explosion-proof chiller?
Check if it is the cause of the failure of the enclosed explosion-proof chiller. This selection must be accurate. If the model is not in place, the required cooling effect will not be achieved. It is recommended that the user will need it when purchasing the enclosed explosion-proof chiller. The cooling capacity and other parameters are provided to the chiller manufacturer, and professionals will select the model for you to achieve the required cooling effect.
The enclosed explosion-proof chiller has higher requirements for the working environment, because it is cooled by hot air circulation. If the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect. There is more dust on the surface of the compressor, which leads to slow heat dissipation of the compressor and indirectly affects the cooling effect. There is leakage or shortage of refrigerant in the enclosed explosion-proof chiller, which leads to a decline in the cooling effect of the chiller. The accumulation of debris or sludge in the evaporator causes the flow rate to slow down, which affects the evaporation and condensation capacity and reduces the cooling effect.

The dust in the condenser of the enclosed explosion-proof chiller will affect the heat dissipation effect. The equipped unit is operating at full load, and the ambient temperature rises, resulting in insufficient cooling power and thus affecting the cooling effect.
Insufficient refrigerant, which is what we often call Freon, will also lead to poor cooling performance of the enclosed explosion-proof chiller. During the operation of the chiller, the liquid refrigerant in the evaporator continuously absorbs heat from the water and starts to evaporate. After the compressor is compressed and throttled by the expansion valve, it becomes a low-temperature and low-pressure refrigerant and enters the evaporator to continue. Circulation, if the use time is too long, the refrigerant will volatilize, which will affect the cooling effect.
When the filter of the enclosed explosion-proof chiller is blocked, it affects the heat exchange effect of the condenser, and the cooling effect of the whole machine is not good. It needs to be checked regularly and cleaned. When the filter is seriously clogged, it is recommended to replace the new filter drier.
관련 권장 사항
-
소형 수냉식 냉각기가 냉매를 충전할 때 따라야 하는 방법
1190우리 생활에서 누구나 냉방에 매우 익숙하다고 생각합니다. 중앙 공조 및 산업 생산 공정 냉각 산업에서는 소형 수냉식 냉각기가 더 일반적입니다. 이 장치는 압축기로 구성됩니다 ...
세부 정보 보기 -
폐쇄 순환 냉각 시스템 디버깅 주의 사항
1126폐쇄 순환 냉각 시스템은 시운전 중에 몇 가지 일반적인 문제에주의를 기울여야합니다. 디버깅 작업을 잘 수행하십시오. LNEYA 제조업체는 사용자가 작업 할 준비가되었을 때만 더 나은 디버깅을 할 수 있음을 사용자에게 상기시킵니다. 준비 ...
세부 정보 보기 -
Analysis of Common Faults in New Energy Vehicle Power Battery Test System
995If the new energy vehicle power battery pack leaks, the general fault manifestation mode: the meter OK light does not light, the meter prompts to check the power system, the high voltage system leakage fault, disconnect the battery pack and the b...
세부 정보 보기 -
리액터용 장비는 어떻게 선택하나요?
904원자로의 장비 선택은 다음 사항에 따라 측정해야 합니다: 1. 가열 방법: 일반적으로 전기 가열은 3톤 이상이어야 하며, 외부 하프 파이프의 경우 3톤 미만에서 3톤 이상이어야 합니다.
세부 정보 보기