Analysis of Common Faults in New Energy Vehicle Power Battery Test System
If the new energy vehicle power battery pack leaks, the general fault manifestation mode: the meter OK light does not light, the meter prompts to check the power system, the high voltage system leakage fault, disconnect the battery pack and the body all connections (positive and negative lead, sampling line interface) .
Close the maintenance switch assembly, multimeter test battery pack parameters: closed maintenance switch, use a multimeter to measure the total voltage of the power battery V, use a multimeter to measure the positive and body voltage V1, use a multimeter to measure the negative and body voltage V2, multimeter pen replacement Parallel fixed value resistance meter pen, and set the gear position to the resistance file, measure the fixed value resistance value R, multimeter table position back to the DC voltage file, measure the parallel resistance, the positive pole and the body voltage V1, measure the parallel resistance, the negative pole and the body After the voltage V2 is measured, disconnect the maintenance switch.
If a new energy vehicle battery encounters a temperature-type fault, it means that the vehicle does not have an OK file. The instrument panel indicates that the power battery temperature is too high. After a temperature alarm occurs, the manager, the wiring harness, and the like need to be excluded (replacement manager, The manager and the battery pack are connected to the sampling harness); if the fault persists after the replacement, it is judged that the power battery is faulty.
Wuxi Guanya New Energy Battery Cooling Test System Platform reminds that if the power battery is seriously unbalanced, check the vehicle for full charge and charge, and switch BMS test 80%, 50%, 0% single-cell battery voltage data flow, observe and compare If the low battery voltage is the same, the fault still replaces the power battery.
If there are other faults in the battery pack in the automotive power battery test system, it is recommended to contact the battery manufacturer for processing.
Related recommendations
-
Heat transfer oil for cooling and heating temperature control systems in the chemical and pharmaceut
2331The cooling and heating temperature control system, also known as a high and low temperature circulator or dynamic temperature control system, is a temperature control equipment used in the pharmaceutical and chemical industry to provide cold and ...
View details -
Application Note of Low Temperature Refrigerator for Cold Shrink Assembly of Automobile Engine Parts
2720Engine assembly is carried out in a low-temperature environment below minus 30°C in a low-temperature refrigerator. The mainstream automobile engine manufacturers have their own low-temperature assembly workshops. Engines assembled in a low-temper...
View details -
Temperature requirements for pharmaceutical process bioreactors and crystallization equipment
2512The following is a specific explanation of the temperature requirements for both: Temperature requirements for bioreactors: bioreactors are mainly used for biological processes such as fermentation and cell culture, where temperature control is cr...
View details -
Simulation control of temperature change in the cooling and heating temperature control system of th
1768Industrial cooling and heating temperature control system is a temperature control equipment used in the cooling and heating process of reaction kettle in the pharmaceutical and chemical industry. What are the characteristics of lneya's equipment?...
View details