How to solve the problem that the cooling pump centrifugal pump power consumption becomes larger?
There are many opportunities for the centrifugal pump in the chiller, but the failure of the centrifugal pump will affect the use of the chiller. Therefore, do not worry if the centrifugal pump power becomes larger, find out the cause in time, and solve it in time.
The cooling machine centrifugal pump works by rotating the impeller to make the water centrifugally. Before the pump starts, the pump casing and the suction pipe must be filled with water, and then the motor is started, so that the pump shaft drives the impeller and water to perform high-speed rotary motion. Centrifugal movement occurs, and is thrown to the outer edge of the impeller, and flows into the water pressure pipe of the water pump through the flow path of the volute pump casing.
The reasons for the increase in power are summarized below, as follows:
The matching of the cooling machine pump is unreasonable. The pressure and displacement of the modified pump or the replaced pump are improved compared with the original pump, and the power of the motor is too small; the outlet valve is too large and the pump pressure is too low. The pump displacement exceeds the specified value of the nameplate too much, and the deviation from the working point is too much; the cooling machine packing pressure is too tight; the cooling machine power supply voltage is too low, the current exceeds the rated value; the cooling motor or pump is seriously different, the vibration is serious; the pump The friction between the inner rotor and the stator component is severe; the rotor of the cooling motor is turbulent, the position is not correct, the journal step and the bearing end face or the coupling and the oil seal cover are ground; the cooling coupling coupling buffer damping rubber ring is too tight, and the pump pushes forward The motor coupling and the bearing cover are ground; the balance plate of the cooling machine is not opened, the grinding is severely performed, and the balance return pipe is hot; the radial clearance of the pressure relief sleeve or the balance plate is too small, the deflection is too large, and the operation is worn; When the cooling pump is started, serious internal faults occur, such as the mouth ring, the bushing falling off or the matching clearance is too small; the pump shaft is too rigid and bending deformation.

In the face of the above-mentioned failure of the centrifugal pump of the cooling machine, according to the situation on the site, timely take corresponding measures to deal with it, get in touch with the power supply unit, and adjust the supply voltage to within the specified range;
Adjust the opening degree of the outlet valve to make it run at the normal working condition; properly control the pump pressure and displacement, reduce the running current of the motor; adjust the tightness of the packing gland.
If the above measures can not be eliminated, the pump should be stopped for inspection and treatment. Specific treatment measures: 1 re-empting and draining the air inside the pump; 2 checking and adjusting the lubricating oil pressure, repairing or replacing the bearing bush; 3 replacing the coupling minus Shock rubber ring; 4 repair or replace the balance plate; 5 to carry out three guarantee operations, repair and replace damaged parts; 6 with the professional team to deal with motor failure.
If you still can’t solve the cooling centrifugal pump in time, contact the professional manufacturer for technical guidance!
관련 권장 사항
-
냉각 온도 조절기 냉각기가 갑자기 시작되지 않는 이유
1086냉각 온도 조절기 칠러를 사용하는 동안 예기치 않은 상황이 발생하면 다양한 문제를 효과적으로 해결하기 위해 문제를 해결하기 전에 구체적인 이유를 즉시 파악하는 것이 중요합니다. 예를 들어, 재 ...
세부 정보 보기 -
Semiconductor Testing Dual Channel heating Circulator Unit
837The dual channel heating cycler in semiconductor testing refers to a device used to test semiconductor devices (such as power semiconductors), which can simultaneously control two independent testing channels to perform heating and cooling...
세부 정보 보기 -
반응기의 자동 온도 제어 시스템의 수냉식 냉각기의 비상 사태용
886In the pharmaceutical and chemicalproduction, the automatic temperature control system of the reactor is widelyvisible. In order to ensure the safe production of the enterprise, what shouldusers pay attention to when facing unexpected situation...
세부 정보 보기 -
Working characteristics of industrial high temperature and low temperature cooling system
1030The industrial high-temperature and low-temperature cooling system is mainly used for the monitoring and control of temperature, pressure, flow, liquid level, humidity, pH value and other parameters. It has the characteristics of high control acc...
세부 정보 보기