10마력 냉동고 파이프 청소 지침
10마력 냉동기는 LNEYA의 산업용 저온 가공 장비입니다. 냉각기를 사용하여 냉각하는 과정에서 파이프 라인이 제대로 청소되지 않으면 냉장고를 사용하므로 파이프 라인 청소가 필요합니다. 그를 제거하십시오 ...
Remove the heat transfer medium before cleaning the 10hp freezer. Connect a suitable drain to the drain and allow it to flow into a suitable container (make sure the tube and container match the heat transfer media). Open the drain valve, the heat transfer medium flows from the external application to the pump chamber and then flows from the drain port to the container at low temperature to remove the heat transfer medium. Be sure to take protective measures to prevent low temperature frostbite. Open the freezer filling port and carefully purge the heat transfer medium in the system by carefully blowing nitrogen into the heat transfer medium outlet (pressure below 3BAR).
Replace 10hp freezer heat transfer oil / internal cleaning, please be careful not to use acetone as a cleaning solvent. Failure to do so will destroy the tightness of the 10hp freezer. After discharging according to the previous section, depending on the heat transfer medium, a lot of residue of the heat transfer medium remains in the pump chamber and the inner container. Fill in a suitable solvent, such as a silicone oil cycle to clean the internal components, including the pump chamber, internal vessels, conduits, etc. Depending on the situation of the contamination, it may be necessary to repeat this method several times. Then let the instrument open all the drain valves and connections. Please note that before using the new heat-conducting medium to control the temperature in ultra-low temperature operation, please be sure to remove the moisture in the system. Otherwise, the viscosity of the heat-conducting medium will increase when the temperature is low, and the heat transfer capacity will be reduced.
When cleaning the 10hp freezer pipe, be careful that the heat transfer medium must be cleaned, otherwise the media will cause the freezer to malfunction.

관련 권장 사항
-
Classification and advantages and disadvantages of water-cooled chillers
1397Industrial chillers are divided into air-cooled industrial chillers and water-cooled industrial chillers. Today we will discuss the classification, advantages and disadvantages of water-cooled chillers. Advantages of water-cooled chillers: 1. Inte...
세부 정보 보기 -
고온 및 저온 통합 기계 장비 차단 지침
988고온 및 저온 통합 기계 장비가 장시간 작동하는 경우 관리하지 않으면 고온 및 저온 통합 기계 장비가 막힐 수 있습니다. 장비 막힘을 해결하는 방법은 무엇입니까? 전나무 ...
세부 정보 보기 -
Function of Water Pump of Industrial Water Chiller
1290The water pump is one of the important auxiliary components of the refrigeration system of the industrial water chiller. Many industries will use the industrial water chiller, but many people don't know much about the equipment. This time, lneya r...
세부 정보 보기 -
Operating Principle of LNEYA Industrial Air Cooled Chillers
1409Industrial Air Cooled Chillers is a heatexchanger which USES air to cool the hot fluid. The hot fluid in the tube isheated through the exchange of heat between the tube wall, the fin and theoutside air, which is usually supplied by the ventilat...