소형 환경 테스트 챔버 압축기는 유지 보수 후주의를 기울여야합니다.
원심식 소규모 환경 테스트 챔버에서 흡입 회수 장치는 일반적으로 독립 시스템이며, 필요한 경우 응축기와 증발기에 연결된 파이프 라인을 닫아 별도의 유지 보수를 할 수 있습니다. 후 ...
After replacing the compressor in the small environmental test chamber, the pumping recovery device generally uses the automatic mode to open, stop and work during the operation of the unit. Therefore, the oil level of the oil separator of the piston compressor should be strictly monitored. Strictly monitor the level of the refrigerant in the recovery condenser. If the liquid level is not visible, the recovery condenser is not effective. Check whether the coolant line and the filter are blocked. If the non-condensable gas removed by the bleed valve contains more refrigerant gas, check if the float valve at the top of the recovery condenser is stuck.
If the venting valve that is automatically vented in the small environmental test chamber does not open the deflation when the specified pressure value is reached, the operation of the suction recovery device should be stopped and the exhaust valve should be overhauled. Frequent activation of the pumping recovery unit indicates that a large amount of air has leaked into the unit. Before the start of the refrigeration unit or during the start-up process, the manual operation of the suction recovery device is generally adopted. The time of each operation is limited by the decrease of the condensing pressure and the heat of the piston compressor motor casing. Generally, the continuous operation time is less than 30 minutes. If the small environmental test chamber is not used for a long time, it can be turned on for a short time to lubricate the compressor part. If the small environmental test chamber does not need to exclude non-condensable gases, the unit should also be operated for 15 to 20 minutes per day or several days.

The maintenance of the small environmental test box is also inevitable. It is recommended to make regular maintenance plans and carry out maintenance in a timely and effective manner.
관련 권장 사항
-
LNEYA용 서큘레이터란 무엇인가요?
1059냉동 사이클 가열 기계는 가열 및 냉장 기능을 갖춘 실험실 장비이며,이 기기는 주로 생물학적, 화학 및 기타에 사용되는 여러 가지 독점 기술, 고정밀 온도 제어를 사용합니다 ...
세부 정보 보기 -
Collocation Requirements For Lab Water Chiller
1213The lab water chiller is a relatively advanced cryopreservation equipment, which is suitable for blood stations, hospitals, health and epidemic prevention systems, scientific research institutes, electronic industry, chemical medicine, biological ...
세부 정보 보기 -
Small desktop sealed chiller troubleshooting solution
962Small desktop sealed chillers will have more or less failures after long-term use, so how can the compressor be solved if there are some faults? LNEYA specializes in the development and production of small desktop sealed chillers with a temperatur...
세부 정보 보기 -
What should we pay attention to when purchasing cooling equipment for industrial chiller units?
861When many customers buy refrigeration equipment for industrial chiller units, they don't know what the key points are. Next, let me talk to you. 1. It should be determined according to the use, refrigerating capacity, local power supply, water sou...
세부 정보 보기