The reason why the semiconductor small thermostat is blocked by refrigeration
The small semiconductor small-scale thermostat ice jam is mainly caused by the excessive moisture contained in the refrigeration system. With the continuous circulation of the refrigerant, the moisture in the refrigeration system gradually collects at the capillary outlet, in view of the relatively low temperature at the capillary outlet, the water It forms ice and gradually increases. When it reaches the necessary level, the capillary is completely blocked, the refrigerant does not recur, and the semiconductor small thermostat does not cool.
The main reason for the moisture in the small semiconductor small-scale thermostat refrigeration system is that the electromechanical insulation paper in the compressor contains water, which is the main source of moisture in the system. In addition, the residual moisture of the components of the refrigeration system and the combined pipelines due to insufficient drying; the refrigeration oil and the refrigerant contain more than the allowable amount of moisture; during the installation or maintenance process, the pipeline is in a state of development for a long time, causing moisture in the air to be Inhaled by electromechanical insulation paper and refrigerating machine oil.

In view of the fact that the above causes the water content of the refrigeration system to exceed the allowable amount of the refrigeration system, ice plugging occurs. On the one hand, ice plugs become refrigerants, and semiconductor small thermostats do not normally cool; on the other hand, water also reacts with refrigerants, synthesizes hydrochloric acid and hydrogen fluoride, and turns into corrosion of metal pipes and components. It will cause insulation damage of the electromechanical winding, and at the same time it will become the smell of the refrigerating machine oil, and the compressor will be smooth, so the water in the system is forced to operate at a relatively low limit.
The semiconductor small thermostat should try to avoid the blockage of its refrigeration system. If there is a blockage, it is also necessary to contact the technician to solve it in time.
관련 권장 사항
-
-
열유 난방 시스템 설치 및 고장 분석
1341열전달 오일 난방 시스템 장치를 설치할 때 설치 중 일부 결함을 피하기 위해 시스템에주의를 기울여야합니다. 결함이 발생하면 열전달 오일과 관련된 결함을 이해해야합니다.
세부 정보 보기 -
Several Attention Aspects of Ultra Low Temperature Freezer
1280The performance of ultra low temperature freezer will be reduced naturally due to long-period application in all fields. Thus, Guanya Refrigeration Technology Co., Ltd, leader in ultra low temperature freezer manufacturers has to remind every user...
세부 정보 보기 -
10마력 냉동고 파이프 청소 지침
105510마력 냉동기는 LNEYA의 산업용 저온 가공 장비입니다. 냉각기를 사용하여 냉각하는 과정에서 파이프 라인이 제대로 청소되지 않으면 냉장고를 사용하므로 파이프 라인 청소가 필요합니다. 그를 제거하십시오 ...
세부 정보 보기