Small desktop sealed chiller troubleshooting solution
Small desktop sealed chillers will have more or less failures after long-term use, so how can the compressor be solved if there are some faults?
LNEYA specializes in the development and production of small desktop sealed chillers with a temperature control range of 5 to 35 degrees. The temperature of the heat transfer liquid can be adjusted, and the temperature control accuracy is high with an accuracy of ±0.1 degrees. The device uses branded accessories for stable performance and can work 24 hours a day.

The small tabletop sealed chiller can be applied to cooling the heat generating portion of the semiconductor manufacturing apparatus, cooling the heat generating portion of the laser device, and analyzing and detecting the cooling of the heat generating portion of the machine. Some models are specially upgraded, not only for cooling, but also for heating. The temperature control range can reach 5 to 50 degrees, which greatly improves the performance of precision cooling water circulation equipment.
The fault of the small desktop sealed chiller should be comprehensively analyzed from the data and materials of the battery test water cooling unit obtained by means of indicating instruments and watching, listening, touching, etc., to find out the basic causes of the fault and consider what kind of emergency measures should be taken. How to save time, save materials, and save money to troubleshoot.
For small desktop sealed chiller compressor failure In order to prevent compressor overload or overheating, the motor has built-in six PTC thermistors. Generally, L and N are power supplies, and 11, 14 are connected to the control loop.
As one of the core devices in a small benchtop sealed chiller, the condenser acts to transfer the heat of the refrigerant to the surrounding medium (water or air), condensing the high temperature and high pressure ammonia vapor into a liquid. For example, in the water-cooled box type water chiller, the condenser is a high-efficiency threaded steel pipe. The two end covers can be interchanged to change the direction of the water pipe. The water pipe process has multiple circuits, and each condenser and the compressor capacity are mutually The straight-through water pipe is easy to clean and maintain.
The small desktop sealed chiller is a heat transfer medium that uses cooling liquid (usually used as cooling liquid, low temperature common synthetic cooling liquid, such as aqueous solution of ethylene glycol, etc.) to transfer heat generated by other instruments or equipment that need to be cooled. The refrigeration system dissipates heat to the outside of the unit, ensuring that the unit operates within the normal temperature range.
For the failure of the small desktop sealed chiller, it is necessary to strictly follow the relevant safety procedures. Do not assemble it yourself if the situation is unclear, and disassemble it at will, and contact the manufacturer for repair.
관련 권장 사항
-
Refrigerating Output of Low Temperature Cooling Circulator
947The refrigerating output of low temperature cooling circulator varies with different working conditions. So, when the process calculation is carried out at the beginning, it is necessary to set an allowance for the refrigerating output of the heat...
세부 정보 보기 -
5L glass reactor thermal oil heating system
7755L glass reactor is a common laboratory equipment used for various chemical reactions. In order to ensure that the reaction is carried out at the required temperature, it is usually necessary to equip it with a heating system. Thermal oil (a...
세부 정보 보기 -
냉각 순환 시스템은 증류기에서 비응축성 테일 가스를 수집하는 데 사용됩니다.
1050대부분의 정류탑은 2단계 응축 방식입니다. 첫 번째 단계는 냉각수를 사용하여 주로 상단 증기를 응축하고 두 번째 단계는 냉각수 또는 에틸렌 글리콜을 사용하여 주로 테일 가스를 처리하고 소량을 제거하는 데 사용됩니다 ...
세부 정보 보기 -
Low temperature chiller unit in the production of PGA catalyst auxiliary materials
828Low temperature chillers play an important role in the production reaction process of polyglycolic acid (PGA) and its catalysts and additives. The synthesis and post-treatment process of polyglycolic acid often involve exothermic reactions, ...
세부 정보 보기