초고온 소재 냉온 충격 박스 냉장 오일
The ultra-high temperature material impact test chamber test device has too much frozen oil in the evaporator, which can also cause insufficient cooling and cause slow cooling. The oil stored in the evaporator of the ultra-high temperature material impact test chamber test device can be directly judged by the hot and cold boundary line of the oil surface. If the oil level is too high, it should be released in time.
Some Freon and refrigerating machine oil dissolve each other. Therefore, when the refrigerant in the refrigeration system of the ultra-high temperature material impact test chamber test device is circulating, it is inevitable that the refrigerating machine oil will remain in the various components, and the residual oil in the heat exchanger will affect Heat transfer coefficient. Especially when the refrigerating machine oil enters the evaporator of the test device, if the structural design or installation is unreasonable, the ultra-high temperature material impact test device will only enter or reduce the refrigerating machine oil, so that the residual refrigerating machine oil in the evaporator is more The more you come, the more serious the heat absorption effect, and the lack of cooling capacity. If you don’t handle it at this point, the temperature will not drop. Therefore, you must carry out the oil draining work.

How to judge that the ultra-high temperature material impact test chamber test device has more refrigeration oil in the evaporation tube and affects the refrigeration is a difficult thing. In the case of the ultra-high temperature material impact test device, there is a significant anomaly, that is, the hoarfrost on the evaporation tube is sparsely pulled, incompletely formed, and is defrosted, if there is no other fault, then It is likely that there is too much residual refrigeration oil in the evaporator tube. To remove the freezer oil in the evaporator of the ultra-high temperature material impact test chamber test device, it must be removed, purged and dried. For the tube type evaporator, it is inconvenient to disassemble, the inlet of the test device evaporator can be blown with compressed air, and then the tube is baked with a blowtorch.
There are also many types of evaporators for the ultra-high temperature material impact test chamber test device. Once there are more refrigeration oils, we need to solve them in time.
관련 권장 사항
-
Dynamic and accurate temperature simulation for test benches in the automotive industry
955Quality and safety testing are the core elements of the overall development and production process of the automotive industry. With KRY-475 and 455 process cooling circulators, we provide customers with a perfect temperature control solution for p...
세부 정보 보기 -
온도 요구 사항을 충족하기 위한 반도체 테스트 냉각기 제어 방법
1110바이오 제약 분야에서는 효소의 활성과 제품 생산을 제어하기 위해 고정밀 온도가 필요하고, 화학 산업 분야에서는 화학 반응이 안정적으로 진행될 수 있도록 특정 온도가 필요하며, 전자...
세부 정보 보기 -
Daily maintenance method of heat transfer oil cooling and heating cycle machine
1165The heat-conducting oil cooling and heating cycle machine is a supporting set of various reactors in the pharmaceutical and chemical industry. The reactor can be used for cooling or heating, and has a high energy efficiency ratio. It does not requ...
세부 정보 보기 -
Thermostatic bath SC of Lneya refrigeration company
1498Thermostatic bath of Lneya refrigeration company is widely used for drying, distillation, concentration, dipping in chemical reagents, pharmaceutical and biological products, and can also be used for thermostatic bath heating and other temperature...
세부 정보 보기