How To Choose The Screw Type Water-Cooled Chiller
Compared with the similar chillers, the screw type water-cooled chiller has many advantages. We as one of the top chiller manufacturers share you more.
1. The temperature of the heat conducting liquid can be adjusted to any temperature you want, and it runs smoothly.
2. Using Aspera, Danfoss, Maneurop, Copland and other compressors of international famous brands, stable performance, able to work continuously. Compared with other similar equipment, product performance occupies the dominant position.
3. The design of screw type chiller is more humanized, flexible and convenient to use.
4. Though the microcomputer temperature controller, the temperature number on the equipment can be displayed, the adjustment unit is 0.1 degrees, the precision is quite high, the temperature range is of 5 degrees ~35 degree adjustable, in this temperature range you can adjust any temperature you want, if the temperature is out of range you can customize other refrigeration equipment.
5. Adopt hot gas bypass to save energy and improve control accuracy.
6. The use is more safe. Once the failure occurs, don’t worry, there are a variety of fault alarms (over-temperature alarm, sensor alarm, high pressure alarm, compressor overheating alarm) to come to early warning.
7. It has a boot delay protection, so that you can use at ease.
8. All parts are safely grounded.
9. High performance circulating pump can ensure 24 hours of continuous operation.
관련 권장 사항
-
What are the main points for regular maintenance of the recirculating chiller?
978Recirculating chillers are used frequently in the industry, and the heat generating parts of various devices require recirculating chillers, so operating efficiency is very important. During the running time of the recirculating chiller, it is nec...
세부 정보 보기 -
What are the conditions for the decarboxylation reaction? How to control the temperature of heating?
1241The decarboxylation of aromatic acids is easier than that of fatty acids. For example, benzoic acid can be decarboxylated by adding a little copper powder as a catalyst in quinoline solution and heating. When a strong electron-withdrawing group i...
세부 정보 보기 -
폐쇄 순환 냉각 시스템 디버깅 주의 사항
1125폐쇄 순환 냉각 시스템은 시운전 중에 몇 가지 일반적인 문제에주의를 기울여야합니다. 디버깅 작업을 잘 수행하십시오. LNEYA 제조업체는 사용자가 작업 할 준비가되었을 때만 더 나은 디버깅을 할 수 있음을 사용자에게 상기시킵니다. 준비 ...
세부 정보 보기 -
유리 반응기는 어떻게 선택하나요? 온도 제어 시스템을 맞추는 방법은 무엇인가요?
1006유리 주전자 반응기는 많은 실험실 장비에 필요하며 일반적으로 온도 제어 시스템과 함께 사용됩니다. 화학 및 제약 분야에서 수입 유리 반응기는 기본적으로 필수품이며 냉장 가열 ...
세부 정보 보기