Immersion phase change liquid cooling system
A large amount of data throughput and calculation makes the data center, which is the “brain” of emerging technologies such as artificial intelligence and big data, face unprecedented challenges in energy consumption and heat dissipation. Liquid cooling technology and liquid cooling data centers for equipment such as liquid cooling servers have emerged as the times require.
In the working state, each heating component will generate heat, causing the coolant to heat up. When the temperature of the cooling liquid rises to the boiling point corresponding to the system pressure, the cooling liquid undergoes a phase change, changing from a liquid state to a gaseous state, and absorbs heat through the heat of vaporization to realize heat transfer, which is the most energy-saving and efficient refrigeration in liquid cooling model.
Immersion cooling medium (such as fluorinated liquid), special cooling liquid has high insulation, low viscosity, non-flammable characteristics, and can ensure chemical inertness and stability within the operating range. However, due to the price and loss of fluorinated liquid media, the overall operating cost is high. Our LNEYA liquid-liquid circulation distribution cooling system was born specifically for this situation, which greatly reduces the loss of fluorinated liquid.
The core components of the cold plate liquid-cooled server effectively reduce the PUE of the data center.
Among the eight major nodes of the computing hub in the future, the PUE of large and above data centers in East China and large and above data centers in western regions with a favorable climate should drop below 1.25. Due to its obvious advantages, liquid cooling has become the main cooling technology for data centers. Among them, the cold plate liquid cooling technology is mature and ecologically perfect. As the core component of the cold plate liquid cooling server, the cold plate also plays an important role in effectively reducing the PUE of the data center.
Liquid-cooled data centers should take comprehensive reliability measures at all levels of servers, cabinets and micro-modules. LNEYA cold plate liquid cooling modular data center solution takes a single module as a unit, integrates IT cabinets, power distribution units, closed components, refrigeration units, wiring and other functionally independent units to realize the complete functions of the data center. It can be flexibly disassembled and transported, which not only saves the space of the computer room but also expands the class, and realizes rapid deployment in batches.
7 * 24 무료 상담 및 종합 솔루션 제공


이메일: sales@cnzlj.com
WhatsApp: 086 13912479193
관련 권장 사항
-
Introduction to cold plate liquid cooling system products and equipment
1153Introduction to cold plate liquid cooling chiller
세부 정보 보기 -
LNEYA data center liquid cooling solution Liquid Cooled CDU Distribution Unit
1424LNEYA data center liquid cooling chiller CDU
세부 정보 보기 -
Battery test cooling device Chiller common configuration instructions
1329Under normal use, the battery test cooling device Chiller needs to be discovered in time when any part of the abnormality occurs. This requires a clear understanding of the basic configuration of the battery test cooling device Chiller. The batter...
세부 정보 보기 -
반도체 제조 기업에 가열 서큘레이터 장비가 필요한 이유는 무엇일까요?
1129온도 제어 정확도: 반도체 제조 공정은 온도 제어에 대한 요구 사항이 매우 엄격합니다. 가열 순환기는 정밀한 온도 제어를 제공하여 온도가 일정하게 유지되도록 보장할 수 있습니다.
세부 정보 보기 -
초저온 재순환 냉각기의 일상적인 유지보수 팁은?
1033시동 후 초저온 재순환 냉각기의 정상적인 작동을 보장하려면 초저온 재순환 냉각기의 응축기가 열 방출이 양호해야하며 그렇지 않으면 고온 보호 기능이 ...
세부 정보 보기 -
Operation instructions for cooling and heating system of reactor
1139The reactor cold and hot switching integrated machine is a cooling and heating temperature control equipment applied in various industries. How much do you know about the reactor cold and hot switching integrated machine? In the pharmaceutical, ...
세부 정보 보기
상담 신청하기
24시간 이내에 답변 드리겠습니다.