LNEYA data center liquid cooling solutionLiquid Cooled CDU Distribution Unit
Cold plate liquid cooling CDU-15kW
LNEYA relies on its strong R&D, construction, and operation and maintenance capabilities in the field of data centers to launch a cold-plate liquid-cooled CDU with a new air-liquid architecture. Building construction and renovation of old machine rooms, with excellent PUE indicators throughout the year, green, energy-saving, safe and reliable operation.

Applications: Renovation of small and medium-sized old data center
Energy saving, high efficiency and superior performance
Air-liquid structure, heat dissipation up to 12KW, green and energy-saving, system PUE≤1.2
Standard plug-in design, flexible layout, height is only 5U. Improve the rate of cabinets in the computer room
Front, side inlet, rear outlet air duct design, optimized airflow organization, cold and hot aisle isolation
Easy to install and easy to maintain
Does not involve the primary side pipeline layout, reducing the risk of pipeline laying, engineering quantity and water entering the machine room
Modular design, highly integrated products, easy installation, easy maintenance interface, standard quick connection, two-way cut-off of the flow channel, direct plug-in and maintenance of the pipeline on site
Renovation is simple. The old computer room can rely on the existing refrigeration system, only
Intelligent optimization of remote operation
System status analysis, real-time regulation of refrigerant flow, flow velocity and air volume, load balancing
Liquid product touch screen on-site and host computer remote centralized monitoring, human-computer interaction
Friendly interface
Anti-condensation control, liquid leakage detection, enhanced anti-interference design, high stability Support Modbus-RTUTCPMP communication
Safe and reliable system stability
Double-pump 2N redundant frequency conversion design, automatic switching in case of failure; when the two pumps are running at the same time, overclocking can increase the heat transfer by about 10%
Low-noise dual-fan design, when a single fan fails, the entire liquid cooling system will not stop
Expansion tank for pressure stabilization, full-scale group system design, leakage concealment reduction
High-efficiency pure copper micro-channel heat exchanger, highly compatible with pure steel liquid cold plate, improving system reliability
Introduction to cold plate liquid cooling system products and equipment
Introduction to cold plate liquid cooling chiller
로딩 중...
이미 마지막 에피소드에 도달했습니다!
7 * 24 무료 상담 및 종합 솔루션 제공


이메일: sales@cnzlj.com
WhatsApp: 086 13912479193
관련 권장 사항
-
Immersion phase change liquid cooling system
1186What is immersion phase change liquid cooling system?
세부 정보 보기 -
Introduction to cold plate liquid cooling system products and equipment
1152Introduction to cold plate liquid cooling chiller
세부 정보 보기 -
차량용 충전기 냉각 시스템의 냉각 오일 교체시주의 사항
842자동차 충전기의 냉각 시스템은 작동 중 냉각 오일의 상태에 주의를 기울여야 합니다. 컴프레서를 시동한 후 오일 온도와 오일 압력의 변화를 주의 깊게 관찰하십시오. 오일이 바뀌면 ...
세부 정보 보기 -
What are the characteristics and application scope of cryogenic refrigeration circulators?
1195Specializing in the development and production of low-temperature refrigeration circulators, the refrigeration temperature range is from -120 degrees to -30 degrees. Today, let us take a look at the characteristics of low-temperature refrigeration...
세부 정보 보기 -
Start-up work for new energy thermal management
1038In the pipeline selection of new energy thermal management, if the use of improper/damaged hoses and/or hose joints will result in injury, the new energy thermal management is limited by the temperature, caliber, installation method, etc. Tube, me...
세부 정보 보기 -
Temperature requirements for ion implantation chillers in semiconductor manufacturing processes
884Ion implantation is an important step in semiconductor manufacturing processes to precisely dope and control the electrical properties of semiconductor materials by implanting high-energy ions into them. This process generates a lot of hea...
세부 정보 보기
상담 신청하기
24시간 이내에 답변 드리겠습니다.