Characteristic Analysis of Industrial Air Cooled Chiller
Industrial air-cooled chillers are generally integral machines, that is, evaporator, compressor and condenser are made together. For a slightly high-power air-cooled industrial chiller, the heat dissipation of the condenser cooling fan needs to be considered. Since the heat exchange source of air-cooled chiller is air and equipped with special fan, it is called “air-cooled chiller”. It is widely used in medical, biological, chemical, laser, metallurgy, equipment manufacturing, electroplating, plastic processing and other industries.
Working principle of air-cooled industrial chiller: different from the traditional water-cooled chiller, the air-cooled chiller does not need the cooling capacity brought by the cooling tower, so it avoids more investment, and is easy to install and manage. Casters are equipped at the bottom of the chiller, which can be moved to cycle between different working areas. This saves a lot of unnecessary fixed investment, and cold water can be discharged directly by connecting power supply and water pipe. According to the design requirements, the outlet water temperature is generally 2 ℃, 0 ℃, -5 ℃ and -15 ℃. When the temperature is below zero, the refrigerant needs to be mixed for heat exchange. The commonly used refrigerant is ethylene glycol.
Similar to the conventional chiller, the air-cooled chiller also has a fixed refrigeration cycle route. The principle is to use the inverse Carnot effect, which is similar to the current household air conditioner, but the system structure of the refrigeration loop is improved, so the cop (energy efficiency ratio) is often very high.
Characteristics of industrial air-cooled chiller:
1. All pipelines are of thermal insulation design to prevent local convection of machine pipelines.
2. Cooling temperature range: 5 ℃ ~ 35 ℃.
3. The independent temperature controller has anti freezing protection.
4. Stainless steel insulated water tank.
5. Control line phase sequence protection and high and low voltage switch control of refrigerant system.
6. Hydrophilic optical fin condenser has better heat transfer effect and faster heat dissipation.
7. The compressor and pump are provided with overload protection.
8. The shell and tube evaporator with large capacity is adopted, which has good refrigeration effect and can be applied to the environment with high temperature.
9. R404A refrigerant is used, with good refrigeration effect.
10. R507C environment-friendly refrigerant is optional.
Related recommendations
-
Introduction to heating cooling temperature control system of fermentation tank
2339In the pharmaceutical and biochemical industry, the fermentation tank needs to be equipped with a heating, cooling and temperature control system to control the temperature in the system. The LNEYA refrigeration, heating, cooling and temperature...
View details -
Characteristics of Industrial Constant Temperature Recirculating Chiller
2784Points for attention in the use of industrial constant temperature recirculating chiller Industrial constant temperature recirculating chillers are widely used in pharmaceutical, chemical and laboratory. Next, let's introduce the characteristi...
View details -
Semiconductor laser automatic temperature control equipment accessories fault solution
2287Semiconductor laser automatic temperature control compressor frosting, may be circulating water circulation or valve is not open, check the water valve, all pipelines, to ensure smooth, install short-circuit pipeline. It may be that the circulatin...
View details -
Why is the mode of cooling water circulator mainly water circulation?
1863Cooling water circulator is a way to use water for cooling. With the increase in ambient temperature, many companies have also found that the use of circulating water is increasing. The supplement of circulating water is aimed at the water cooling...
View details
LNEYA Thermo Refrigeration Co.,Ltd