How to deal with the installation of the hot and cold integrated control machine?
Since the thermocouple’s thermal inertia causes the meter’s indicated value to lag behind the measured temperature, this effect is particularly pronounced when performing rapid measurements. Therefore, thermocouples with thinner thermal electrodes and smaller protective tube diameters should be used whenever possible. The protective tube can even be removed when the temperature measurement environment permits.
In the use of hot and cold integrated control machine, usually use materials with good thermal conductivity, thin tube, small inner diameter protection sleeve, in the more precise temperature measurement, use unprotected sleeved bare wire thermocouple, but thermocouple It is easy to damage and should be corrected and replaced in time.
Due to the measurement lag, the amplitude of the temperature fluctuation detected by the thermocouple is smaller than the amplitude of the furnace temperature fluctuation. In order to accurately measure the temperature, a thermocouple with a small time constant should be selected. The time constant is inversely proportional to the heat transfer coefficient. It is proportional to the diameter of the hot end of the thermocouple, the density of the material, and the specific heat. If the time constant is to be reduced, In addition to the thermal coefficient, the error introduced by the insulation of the cold and heat integrated control machine is poor.
The hot and cold integrated control machine protects the tube and the wire plate from excessive dirt or salt residue, resulting in poor insulation between the thermocouple and the furnace wall, which is more serious at high temperatures, which not only causes the loss of the thermoelectric potential but also introduces interference. The error caused by this can sometimes reach Baidu.
The above installation failures should be avoided as much as possible to reduce the error rate of the integrated heat and cold control machine and save the operating cost of the enterprise.
Related recommendations
-
Equipment attention points of laboratory high and low temperature cycle equipment manufacturers
2182In the laboratory, a wide range of experimental instruments are widely used. When the experimental instruments are in operation, they are inseparable from the high-low temperature circulating device refrigeration heating equipment. What should be ...
View details -
TCU temperature control model selection and technical parameter description
2813TCU temperature control is also a two-cycle unit single-fluid temperature control system. When selecting the model, it is very important for the whole temperature control reaction. Only the appropriate reaction system is used to exotherm and absor...
View details -
Cooperation with the strong! LNEYA&Siemens strategic cooperation signing ceremony ended successfully
3787On May 25, 2021, the signing ceremony of strategic cooperation between LNEYA Constant Temperature Refrigeration Technology Co., Ltd. and Siemens (China) Co., Ltd. was held in Wuxi, China. At the signing ceremony, leaders such as Que Yaoyao, dire...
View details -
Why is there air in the reactor temperature control system?
2021The impurity gas in the reactor temperature control system is to increase the condensing pressure of the refrigeration system, thereby increasing the condensing temperature, increasing the exhaust temperature of the compressor, increasing the powe...
View details
LNEYA Thermo Refrigeration Co.,Ltd