Cold and hot shock constant temperature and humidity test chamber operation steps
When selecting the appropriate model of the LNEYA hot and cold shock constant temperature and humidity test chamber, you need to pay attention to the operation and installation steps. The user needs to be well prepared for the installation work.
The hot and cold shock constant temperature and humidity test chamber should be noted before use. The power supply voltage should be turned on. After the fan is started, open the door and select the required impact height. Then close the door and press the up and down position. Then stop rising.
Then, open the door and insert the safety pin to protect it in the future operation. Place the tested object in the center of the thermal shock constant temperature and humidity test chamber, and then place the crossbar on the sample. Hold the battery at the center, dial the safety latch, and close the door. Press the impact button and the falling ball weight is free to drop and complete a test.
The hot and cold shock constant temperature and humidity test chamber should be noted in use. The test sample should be a non-deformed sample or a well-packaged sample to avoid affecting the test conclusion. Before placing the sample for each operation, be sure to insert the full plug. Well, it is strictly forbidden to operate without a safety plug to avoid unnecessary safety accidents.
The installation proposal of the thermal shock constant temperature and humidity test chamber shall be installed by a special operator, and the installation of the external operator shall be avoided as much as possible to avoid damage to the equipment.
Related recommendations
-
-
What type of temperature control system is required for smear preparation in the pharmaceutical industry?
1978In the pharmaceutical industry, negative pressure drying and smear preparation have specific requirements for temperature control, and usually require precise and adjustable temperature control devices to ensure product quality and process sta...
View details -
Effect of evaporator on refrigeration system in special instrument for low temperature experiment
2325The low temperature experiment special instrument is LNEYA's refrigeration heating equipment for the laboratory. The importance of the evaporator is self-evident. So what effect does the evaporator have on the refrigeration system? According to di...
View details -
Heat transfer oil chemical temperature control system product application
1849The heat transfer oil heating and cooling temperature control system is a device with heating or lowering at the same time, that is, when the temperature of the equipped glass reactor, rotary evaporator, extraction equipment and other devices need...
View details
LNEYA Thermo Refrigeration Co.,Ltd