How to Carry On Industrial Low Temperature Chillerstest Of Choosing The Better Company?
No matter what chillers are used, we need to constantly learn about the relevant knowledge of the industrial-low temperature chillers.
Which company’s low – temperature chiller is better? Let me tell you, in order to help you to use the industrial low temperature chillers, you have to know these related knowledge of test.
Temperature detection of inlet and outlet
When the industrial low temperature chiller is being used, the thermometer of the inlet and outlet of the system is checked through the control system of the unit half an hour after starting up, which can read the inlet temperature and outlet temperature of the industrial low-temperature chiller. Ensure that the temperature difference between inlet and outlet water is not too large, once it is too large, the water flow may be shown to be small, which may cause the normal operation of the industrial low-temperature chiller.
Water pressure detection of inlet and outlet pipes
It is necessary to test the outlet and inlet water pressure values of industrial low-temperature chillers, and then check the instructions to see how much water flow is under normal conditions to judge whether the refrigeration system is normal. Which company’s low – temperature chiller is better? Let me tell you. We can judge which section of the pipe resistance value is larger, and make the corresponding rectification plan from the line.
Detection of suction temperature of copper tube of compressor
When using industrial low – temperature chillers, after running for half an hour, If the suction temperature of the compressor is detected below 0 degrees, it indicates that the water flow in the heat exchanger does not reach a fixed value. It is easy to cause the drop of evaporation force, which may lead to the refrigerant still absorbing heat in the process of evaporator flowing to the compressor, resulting in the suction temperature of the compressor being lower than 0 degrees.
Current detection during pump operation
During operation, the industrial low – temperature chiller can compare the current in the water pump with the rated current of the chiller. In this way, it can judge whether the current is large or small and detect the operation status of the water system at any time.
These are the methods of testing which company’s industrial low -temperature chiller is better. I hope you can quickly find problems in the chiller when you check it.
관련 권장 사항
-
Failure Analysis of Ultra Low Temperature Chiller Supporting Distillation Equipment
1372Once the freezer used in the matching distillation equipment fails, we need to solve it in a timely and effective manner to avoid affecting the operation of the entire experiment. In the pharmaceutical, chemical and other industries, low temperatu...
세부 정보 보기 -
공랭식 및 수랭식 15P 냉동 장치의 차이점
1243수요 조건이 다르기 때문에 선택한 15P 냉동 장치가 공랭식 및 수냉식 인 경우 차이점은 무엇입니까? 공냉식 15P 냉동 장치에는 본체에 단열 물 탱크와 워터 펌프가 포함되어 있으며, ...
세부 정보 보기 -
공냉식 냉각기의 주요 적용 분야
1193국내외 산업용 냉각기 시장에서 가장 일반적인 산업용 냉각기 장비는 크게 두 가지 유형으로 나눌 수 있으며, 한 유형은 산업용 공냉식 냉각기, 다른 유형은 산업용 물 공동 냉각기입니다 ...
세부 정보 보기 -
Ultra Low Temp Chiller Compressor Common Protection Instructions
912The ultra low temp chiller compressor is a relatively important part of all its components. In the course of operation, certain protective devices are needed to help the compressor operate safely. What specific protection? Let's take a look! The m...
세부 정보 보기