The difference between air-cooled and water-cooled 15P refrigeration units
Because the demand conditions are different, when the selected 15P refrigeration unit is air-cooled and water-cooled, what is the difference?
The air-cooled 15P refrigeration unit contains a heat-insulating water tank and water pump in its body, which is very convenient for installation and movement. However, it requires a higher working environment because it is cooled by hot air circulation. Therefore, if the ventilation effect of the installation workshop is not good, it will directly affect the cooling effect of 15 refrigeration units. In addition, if you want to put the refrigeration unit in a dust-free workshop with humidity requirements, then I advise you to modify the water-cooled. Because of the air-cooled refrigeration unit, water vapor is sprayed on the top of the machine to dissipate heat.
The water-cooled 15P refrigeration unit can be divided into open type, sealed type (some called box type) and screw type. It is necessary to declare that the water-cooled refrigeration unit must be additionally equipped with a cooling tower and a water pump for extracting hot water to dissipate heat. In order to achieve a better cooling effect.
Air-cooled 15P refrigeration units can be used on small systems, most of which are water-cooled. When the water is cold, the main engine is less than the air-cooled. In other words, the cooling efficiency of the water-cooled unit will decrease relative to the long-term operation, and the air cooling will not.
The air-cooled 15P refrigeration unit has a slightly higher investment than the water-cooled 15P refrigeration unit, but the annual operating cost is lower than that of the water-cooled refrigeration unit. The construction cost of the equipment room is relatively small in various refrigeration unit cold and heat source systems. The cost is about half the cost of water-cooled or boilers. The noise and volume of air-cooled chillers are larger than those of water-cooled units. This requires attention.
There is a certain difference between the air-cooled and water-cooled units of the refrigeration unit. I hope that you can understand the proper 15P refrigeration unit model.
Related recommendations
-
Characteristic Analysis of Air Cooled Industrial Chiller
1787Industrial air-cooled chillers are generally integral machines, that is, evaporator, compressor and condenser are made together. For a slightly high-power air-cooled industrial chiller, the heat dissipation of the condenser cooling fan needs to be...
View details -
New energy battery test cooling device compressor fault judgment
2142How to identify the three terminals on the fully enclosed compressor casing of the new energy battery test cooling unit? The resistance between the running end (R), the starting end (S), the common end (C), and the RS is greater than the resistanc...
View details -
LNEYA temperature control system AH series commentary
2279Refrigeration heating temperature control system AH series, suitable for high heat release, suitable for SUS reactor, temperature difference > 150 ° C, can quickly cool high temperature reaction, polymerization reaction and rapid heating and co...
View details -
Detailed introduction of the motor control cooling system Chiller
2745With the continuous development of new energy vehicles, the motor control cooling system Chiller is also under continuous development. The new energy vehicle motor test special chiller can adaptively adjust the cooling capacity of the chiller acco...
View details
LNEYA Thermo Refrigeration Co.,Ltd