Ultra-low temperature refrigeration circulator condenser maintenance instructions
Maintenance is an important task for users of ultra-low temperature refrigeration circulators. Wuxi Guanya LNEYA reminds that the maintenance of the condenser is a relatively important task in its maintenance work. So what should be paid attention to for maintenance?
The condenser of the Wuxi Guanya LNEYA ultra-low temperature refrigeration circulator has a long running time, and the performance will gradually decrease, which will make the condensing pressure of the system higher than the condensing pressure during normal operation. In order not to degrade the properties of the condenser, it is necessary to periodically maintain the condenser.
For the ultra-low temperature refrigeration circulator water-cooled condenser, the problem is mainly to remove scale. The cleaning cycle depends on the water quality. The water quality is poorly cleaned at least once a year. The water quality is good and can be cleaned once every 2 to 3 years.
The condensers used in the ultra-low temperature refrigeration cycle are mainly air-cooled condensers and water-cooled condensers. Depending on the type of condenser, the way to clean the scale is different. The air-cooled condenser uses air as the cooling medium. Due to the dust in the air, some dust will adhere to the outer surface of the condenser fin. If the time is long, the heat dissipation effect of the condenser will be deteriorated, especially in a place with a bad environment, so it should be cleaned regularly. When the condenser of the ultra-low temperature refrigeration circulator is cleaned, if the simple dust can be blown clean with the compressor air, if there is a lot of dirt, the heat-dissipating tube and the fin should be cleaned with a non-corrosive cleaning agent to improve the heat dissipation effect. purpose.
In addition to the maintenance of the condenser, the ultra-low temperature refrigeration circulator needs to pay attention to the maintenance work of other accessories, so the user needs to pay attention to the overall maintenance work.
Related recommendations
-
Organic waste gas recovery unit refrigeration oil requirements description
2946The organic waste gas recovery device is slightly different for different gases. The LNEYA organic waste gas recovery device and the vocs gas condensation recovery device are operated by the principles of condensation and adsorption. The refrigera...
View details -
How to avoid operational errors in fluid heat transfer temperature control systems?
2267During the operation of the fluid heat transfer temperature control system, if the fluid heat transfer temperature control system fails, the main reason is the operation error. So how do we avoid mistakes. 1. The operation of the fluid heat trans...
View details -
Necessity of temperature control in fractional distillation of distillation
1908The pharmaceutical and chemical industry involves many chemical reactions, and with the continuous development of the pharmaceutical and chemical industry, there is a great demand for such instruments. The traditional open cooling and heating con...
View details -
Refrigeration heating and temperature control system of chemical reaction kettle
1936The reaction kettle cooling and heating temperature control system plays a certain role in the temperature control of various materials of reaction kettle, and its temperature control effect affects the results of reaction experiment. The stable o...